Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,199
matching recommendationsSIC | 367 | Electronic Components And Accessories |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0826 # 04 Y:2021 | 04 | 2021 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $979 | $1,631 | Implemented |
MA0826 # 05 Y:2021 | 05 | 2021 | TURN OFF EQUIPMENT WHEN NOT IN USE | $552 | $250 | Not Implemented |
MA0826 # 06 Y:2021 | 06 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $551 | $1,450 | Implemented |
MA0826 # 07 Y:2021 | 07 | 2021 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $323 | $625 | Not Implemented |
LE0507 # 01 Y:2021 | 01 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $746 | $40 | Not Implemented |
LE0507 # 02 Y:2021 | 02 | 2021 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,952 | $14,000 | Not Implemented |
LE0507 # 03 Y:2021 | 03 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,002 | $32,400 | Not Implemented |
LE0507 # 04 Y:2021 | 04 | 2021 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $5,172 | $24,000 | Not Implemented |
DL0190 # 01 Y:2021 | 01 | 2021 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $180 | $0 | Implemented |
DL0190 # 02 Y:2021 | 02 | 2021 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,910 | $0 | Implemented |
DL0190 # 03 Y:2021 | 03 | 2021 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $324 | $50 | Implemented |
DL0190 # 04 Y:2021 | 04 | 2021 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,650 | $0 | Implemented |
DL0190 # 05 Y:2021 | 05 | 2021 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $361 | $1,200 | Not Implemented |
DL0190 # 06 Y:2021 | 06 | 2021 | TURN OFF EQUIPMENT WHEN NOT IN USE | $270 | $0 | Implemented |
DL0190 # 07 Y:2021 | 07 | 2021 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $560 | $550 | Not Implemented |
DL0190 # 08 Y:2021 | 08 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,730 | $2,453 | Not Implemented |
SF0560 # 01 Y:2020 | 01 | 2020 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,246 | $70 | Not Implemented |
SF0560 # 02 Y:2020 | 02 | 2020 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $16,680 | $26,850 | Not Implemented |
SF0560 # 03 Y:2020 | 03 | 2020 | INSTALL OCCUPANCY SENSORS | $4,726 | $14,983 | Implemented |
SF0560 # 04 Y:2020 | 04 | 2020 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $13,118 | $45,851 | Implemented |
SF0560 # 05 Y:2020 | 05 | 2020 | USE SOLAR HEAT TO MAKE ELECTRICTY | $15,645 | $78,611 | Implemented |
CL2007 # 01 Y:2020 | 01 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,082 | $10,098 | Implemented |
CL2007 # 02 Y:2020 | 02 | 2020 | INSULATE BARE EQUIPMENT | $936 | $5,431 | Implemented |
CL2007 # 03 Y:2020 | 03 | 2020 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $58,440 | $10,000 | Not Implemented |
CL2007 # 04 Y:2020 | 04 | 2020 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $637 | $630 | Not Implemented |