Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
154
matching recommendationsSIC | 367 | Electronic Components And Accessories |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0779 # 15 Y:2008 | 15 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $481 | $2,000 | Not Implemented |
UD0779 # 14 Y:2008 | 14 | 2008 | COVER OPEN TANKS | $537 | $360 | Implemented |
UD0779 # 13 Y:2008 | 13 | 2008 | INSULATE BARE EQUIPMENT | $1,228 | $100 | Implemented |
UD0779 # 12 Y:2008 | 12 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,658 | $1,000 | Implemented |
UD0779 # 11 Y:2008 | 11 | 2008 | PAY BILLS ON TIME TO AVOID LATE FEES | $4,322 | $0 | Implemented |
UD0779 # 10 Y:2008 | 10 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,499 | $9,173 | Not Implemented |
UD0779 # 09 Y:2008 | 09 | 2008 | OPTIMIZE PLANT POWER FACTOR | $5,482 | $3,000 | Not Implemented |
UD0779 # 08 Y:2008 | 08 | 2008 | INSULATE BARE EQUIPMENT | $8,895 | $412 | Implemented |
UD0779 # 07 Y:2008 | 07 | 2008 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,679 | $35,000 | Not Implemented |
UD0779 # 06 Y:2008 | 06 | 2008 | IMPROVE COMBUSTION CONTROL CAPABILITY | $75,942 | $100,000 | Implemented |
UD0779 # 05 Y:2008 | 05 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $13,503 | $3,318 | Implemented |
UD0779 # 04 Y:2008 | 04 | 2008 | USE COUNTER-CURRENT RINSING TO REDUCE RINSE WATER VOLUME (GRAVURE) | $13,555 | $500 | Implemented |
UD0779 # 03 Y:2008 | 03 | 2008 | REPLACE BOILER | $17,736 | $65,000 | Implemented |
UD0779 # 02 Y:2008 | 02 | 2008 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $95,648 | $1,000 | Implemented |
UD0779 # 01 Y:2008 | 01 | 2008 | RELOCATE OVEN / FURNACE TO MORE EFFICIENT LOCATION | $255,168 | $200,000 | Not Implemented |
UD0695 # 12 Y:2004 | 12 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $729 | $0 | Implemented |
UD0695 # 17 Y:2004 | 17 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $237 | $213 | Implemented |
UD0695 # 16 Y:2004 | 16 | 2004 | DISCONNECT BALLASTS | $327 | $7 | Implemented |
UD0695 # 15 Y:2004 | 15 | 2004 | AIR CONDITION ONLY SPACE NECESSARY | $339 | $0 | Implemented |
UD0695 # 14 Y:2004 | 14 | 2004 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $420 | $340 | Not Implemented |
UD0695 # 13 Y:2004 | 13 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $397 | $756 | Implemented |
UD0695 # 11 Y:2004 | 11 | 2004 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $784 | $0 | Implemented |
UD0695 # 10 Y:2004 | 10 | 2004 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $1,110 | $0 | Implemented |
UD0695 # 09 Y:2004 | 09 | 2004 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $2,331 | $175 | Implemented |
UD0695 # 02 Y:2004 | 02 | 2004 | AUTOMATE FINISHING PROCESS | $14,454 | $20,000 | Not Implemented |