Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
373
matching recommendationsSIC | 367 | Electronic Components And Accessories |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0246 # 03 Y:1999 | 03 | 1999 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $3,361 | $2,700 | Not Implemented |
AS0246 # 04 Y:1999 | 04 | 1999 | PURCHASE HIGH MATERIALS IN RETURNABLE BULK CONTAINERS | $14,376 | $15,000 | Not Implemented |
AS0246 # 05 Y:1999 | 05 | 1999 | APPLY FOR INVESTMENT INCENTIVES | $7,303 | $60 | Not Implemented |
AS0246 # 06 Y:1999 | 06 | 1999 | AUTOMATE FINISHING PROCESS | $244,608 | $111,104 | Not Implemented |
AS0228 # 10 Y:1998 | 10 | 1998 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $6,873 | $3,125 | Implemented |
AS0228 # 01 Y:1998 | 01 | 1998 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $244,239 | $410,200 | Implemented |
AS0228 # 02 Y:1998 | 02 | 1998 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $955,252 | $4,000,000 | Not Implemented |
AS0228 # 03 Y:1998 | 03 | 1998 | USE WASTE HEAT STEAM FOR ABSORPTION REFRIGERATION | $395,073 | $1,524,052 | Not Implemented |
AS0228 # 04 Y:1998 | 04 | 1998 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $17,372 | $80,000 | Not Implemented |
AS0228 # 05 Y:1998 | 05 | 1998 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $69,699 | $225,000 | Not Implemented |
AS0228 # 06 Y:1998 | 06 | 1998 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $768 | $60 | Not Implemented |
AS0228 # 07 Y:1998 | 07 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $12,819 | $60 | Not Implemented |
AS0228 # 08 Y:1998 | 08 | 1998 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $65,562 | $7,000 | Not Implemented |
AS0228 # 09 Y:1998 | 09 | 1998 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $498,755 | $240 | Implemented |
AS0228 # 11 Y:1998 | 11 | 1998 | INSTALL EQUIPMENT TO MOVE PRODUCT | $11,311 | $14,500 | Not Implemented |
AS0213 # 01 Y:1997 | 01 | 1997 | INSTALL OCCUPANCY SENSORS | $286 | $450 | Not Implemented |
AS0213 # 02 Y:1997 | 02 | 1997 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $287 | $300 | Not Implemented |
AS0213 # 03 Y:1997 | 03 | 1997 | DISCONNECT BALLASTS | $277 | $15 | Not Implemented |
AS0213 # 04 Y:1997 | 04 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $122 | $348 | Not Implemented |
AS0213 # 05 Y:1997 | 05 | 1997 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,357 | $3,800 | Not Implemented |
AS0213 # 06 Y:1997 | 06 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,642 | $1,827 | Not Implemented |
AS0213 # 07 Y:1997 | 07 | 1997 | USE EVAPORATION TO CONCENTRATE MATERIAL | $1,813 | $5,185 | Not Implemented |
AS0213 # 08 Y:1997 | 08 | 1997 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $1,674 | $60 | Not Implemented |
AS0213 # 09 Y:1997 | 09 | 1997 | ADOPT IN-HOUSE MATERIAL GENERATION | $1,487 | $1,020 | Not Implemented |
AS0213 # 10 Y:1997 | 10 | 1997 | INSTALL AN UNINTERUPTABLE POWER SUPPLY | $1,365,942 | $500,000 | Not Implemented |