Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,199

matching recommendations
Reset
SIC 367 Electronic Components And Accessories
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
HO0152 # 03 Y:1997 03 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $482 $400 Not Implemented
HO0152 # 04 Y:1997 04 1997 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $2,241 $6,000 Not Implemented
HO0152 # 05 Y:1997 05 1997 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,832 $10,000 Not Implemented
HO0152 # 06 Y:1997 06 1997 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $6,500 $6,500 Not Implemented
HO0152 # 07 Y:1997 07 1997 IMPROVE CLEANING EFFICIENCY BY MAINTAINING CLEANING SYSTEM $32,500 $6,000 Not Implemented
HO0152 # 08 Y:1997 08 1997 USE EVAPORATION TO CONCENTRATE MATERIAL $3,963 $1,500 Not Implemented
CO0383 # 01 Y:1997 01 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,660 $28,150 Implemented
CO0383 # 02 Y:1997 02 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $557 $980 Implemented
CO0383 # 03 Y:1997 03 1997 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $3,770 $5,700 Not Implemented
CO0383 # 04 Y:1997 04 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $350 $590 Implemented
CO0383 # 05 Y:1997 05 1997 RECOVER AND REUSE COOLING WATER $1,320 $1,580 Implemented
CO0383 # 06 Y:1997 06 1997 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $1,120 $160 Not Implemented
CO0383 # 07 Y:1997 07 1997 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS $1,971,000 $100,000 Not Implemented
DS0086 # 01 Y:1997 01 1997 OPTIMIZE PLANT POWER FACTOR $6,948 $3,808 Implemented
DS0086 # 02 Y:1997 02 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $960 $0 Implemented
DS0086 # 03 Y:1997 03 1997 INSULATE BARE EQUIPMENT $1,477 $2,969 Implemented
DS0086 # 04 Y:1997 04 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,631 $450 Implemented
DS0086 # 05 Y:1997 05 1997 DISTILL CONTAMINATED SOLVENTS FOR REUSE $14,841 $17,500 Not Implemented
DS0086 # 06 Y:1997 06 1997 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $17,888 $10,590 Implemented
DS0086 # 07 Y:1997 07 1997 PAY UTILITY BILLS ON TIME $2,645 $0 Implemented
DS0086 # 08 Y:1997 08 1997 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $16,212 $450 Implemented
UD0508 # 01 Y:1996 01 1996 OPTIMIZE PLANT POWER FACTOR $7,200 $60,000 Implemented
UD0508 # 02 Y:1996 02 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,088 $2,314 Implemented
UD0508 # 03 Y:1996 03 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,041 $8,081 Implemented
UD0508 # 04 Y:1996 04 1996 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $31,719 $11,000 Implemented