Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
246
matching recommendationsSIC | 3674 | Semiconductors And Related Devices |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0066 # 05 Y:1995 | 05 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $973 | $859 | Implemented |
SF0066 # 08 Y:1995 | 08 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $272 | $360 | Implemented |
AS0145 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,240 | $20,292 | Implemented |
AS0145 # 03 Y:1995 | 03 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $363 | $622 | Implemented |
AS0145 # 04 Y:1995 | 04 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $170 | $0 | Implemented |
AS0145 # 05 Y:1995 | 05 | 1995 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,611 | $360 | Implemented |
AS0145 # 06 Y:1995 | 06 | 1995 | INSULATE BARE EQUIPMENT | $222 | $225 | Implemented |
AS0145 # 07 Y:1995 | 07 | 1995 | INSTALL TIMERS AND/OR THERMOSTATS | $1,370 | $3,250 | Implemented |
AS0145 # 08 Y:1995 | 08 | 1995 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $4,575 | $9,100 | Implemented |
AS0145 # 09 Y:1995 | 09 | 1995 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $18,110 | $40,700 | Implemented |
AS0142 # 01 Y:1995 | 01 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $9,046 | $8,327 | Implemented |
AS0142 # 02 Y:1995 | 02 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,963 | $0 | Implemented |
AS0142 # 03 Y:1995 | 03 | 1995 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $8,667 | $25,900 | Implemented |
AS0142 # 04 Y:1995 | 04 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $356 | $100 | Implemented |
AS0142 # 06 Y:1995 | 06 | 1995 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $12,763 | $39,855 | Implemented |
AS0142 # 07 Y:1995 | 07 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $39,071 | $92,498 | Implemented |
AS0142 # 08 Y:1995 | 08 | 1995 | INSTALL OCCUPANCY SENSORS | $4,666 | $8,700 | Implemented |
AS0142 # 09 Y:1995 | 09 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,412 | $3,661 | Implemented |
AS0142 # 10 Y:1995 | 10 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $459 | $600 | Implemented |
CO0315 # 01 Y:1994 | 01 | 1994 | MINIMIZE CONDENSER COOLING WATER TEMPERATURE | $7,950 | $30 | Implemented |
CO0315 # 03 Y:1994 | 03 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,070 | $1,770 | Implemented |
CO0315 # 04 Y:1994 | 04 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,010 | $5,310 | Implemented |
SF0029 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,462 | $10,810 | Implemented |
SF0029 # 04 Y:1994 | 04 | 1994 | INSTALL OCCUPANCY SENSORS | $918 | $1,316 | Implemented |
KG0003 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,276 | $9,920 | Implemented |