Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
14
matching recommendationsSIC | 3674 | Semiconductors And Related Devices |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0050 # 01 Y:2002 | 01 | 2002 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $173,081 | $82,800 | Not Implemented |
MI0050 # 02 Y:2002 | 02 | 2002 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $95,397 | $66,000 | Not Implemented |
MI0050 # 03 Y:2002 | 03 | 2002 | INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS | $53,360 | $5,000 | Not Implemented |
MI0050 # 04 Y:2002 | 04 | 2002 | INSTALL SPECTRAL REFLECTORS / DELAMP | $10,046 | $21,150 | Not Implemented |
MI0050 # 05 Y:2002 | 05 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,880 | $2 | Not Implemented |
MI0050 # 06 Y:2002 | 06 | 2002 | UPGRADE CONTROLS ON COMPRESSORS | $2,860 | $1,338 | Not Implemented |
UF0303 # 01 Y:2002 | 01 | 2002 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $23,984 | $1,074 | Not Implemented |
UF0303 # 02 Y:2002 | 02 | 2002 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $6,229 | $358 | Implemented |
UF0303 # 03 Y:2002 | 03 | 2002 | OPTIMIZE PLANT POWER FACTOR | $5,340 | $24,092 | Implemented |
UF0303 # 04 Y:2002 | 04 | 2002 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,157 | $29,907 | n/a |
UF0303 # 05 Y:2002 | 05 | 2002 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $138,554 | $77,000 | Not Implemented |
UF0303 # 06 Y:2002 | 06 | 2002 | USE EVAPORATION TO CONCENTRATE MATERIAL | $13,509 | $4,995 | Implemented |
UF0303 # 07 Y:2002 | 07 | 2002 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $89,796 | $0 | Not Implemented |
UF0303 # 08 Y:2002 | 08 | 2002 | PAY UTILITY BILLS ON TIME | $7,393 | $0 | Implemented |