Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
989
matching recommendationsSIC | 369 | Misc. Electrical Equipment & Supplies |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0228 # 05 Y:1987 | 05 | 1987 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $9,394 | $7,875 | Not Implemented |
OR0002 # 01 Y:1987 | 01 | 1987 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,190 | $300 | Implemented |
OR0002 # 02 Y:1987 | 02 | 1987 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,568 | $550 | Not Implemented |
OR0002 # 03 Y:1987 | 03 | 1987 | MINIMIZE WATER USAGE | $1,082 | $300 | Not Implemented |
OR0002 # 04 Y:1987 | 04 | 1987 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,563 | $4,730 | Not Implemented |
OR0002 # 05 Y:1987 | 05 | 1987 | OPTIMIZE PLANT POWER FACTOR | $4,962 | $7,398 | Implemented |
OR0002 # 06 Y:1987 | 06 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $543 | $970 | Implemented |
AT0059 # 01 Y:1986 | 01 | 1986 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $447 | $612 | Implemented |
AT0059 # 02 Y:1986 | 02 | 1986 | REDUCE SCRAP PRODUCTION | $3,755 | $2,000 | Implemented |
AT0059 # 03 Y:1986 | 03 | 1986 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $26,952 | $10,000 | Implemented |
AT0059 # 04 Y:1986 | 04 | 1986 | INSULATE BARE EQUIPMENT | $4,635 | $500 | Not Implemented |
AT0059 # 05 Y:1986 | 05 | 1986 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $15,743 | $12,000 | Not Implemented |
AT0059 # 06 Y:1986 | 06 | 1986 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $14,839 | $5,000 | Not Implemented |
AT0059 # 07 Y:1986 | 07 | 1986 | INSULATE BARE EQUIPMENT | $1,232 | $500 | Not Implemented |
AT0059 # 08 Y:1986 | 08 | 1986 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $586 | $0 | Not Implemented |
AT0059 # 09 Y:1986 | 09 | 1986 | IMPROVE LUBRICATION PRACTICES | $2,006 | $0 | Implemented |
ST0061 # 05 Y:1986 | 05 | 1986 | INSTALL AUTOMATIC STACK DAMPER | $757 | $1,410 | Implemented |
ST0061 # 04 Y:1986 | 04 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,593 | $421 | Not Implemented |
ST0061 # 01 Y:1986 | 01 | 1986 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $4,711 | $500 | Implemented |
ST0061 # 02 Y:1986 | 02 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $856 | $0 | Implemented |
ST0061 # 03 Y:1986 | 03 | 1986 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $11,111 | $19,028 | Not Implemented |
KU0168 # 01 Y:1985 | 01 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $2,947 | $125 | Implemented |
KU0168 # 02 Y:1985 | 02 | 1985 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $842 | $200 | Not Implemented |
KU0168 # 03 Y:1985 | 03 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $68 | $912 | Not Implemented |