Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
54
matching recommendationsSIC | 369 | Misc. Electrical Equipment & Supplies |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK1134 # 02 Y:2025 | 02 | 2025 | USE SOLAR HEAT TO MAKE ELECTRICTY | $100,152 | $858,000 | n/a |
OK1134 # 03 Y:2025 | 03 | 2025 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $11,172 | $0 | n/a |
OK1134 # 04 Y:2025 | 04 | 2025 | CHANGE METHOD OF DEIONIZED WATER PRODUCTION | $257,299 | $103,000 | n/a |
OK1134 # 01 Y:2025 | 01 | 2025 | INSTALL OCCUPANCY SENSORS | $262 | $0 | n/a |
OK0639 # 03 Y:2002 | 03 | 2002 | INSTALL OCCUPANCY SENSORS | $258 | $717 | Implemented |
OK0639 # 06 Y:2002 | 06 | 2002 | CHANGE ZONE REHEAT COILS TO VARIABLE AIR VOLUME BOXES | $6,380 | $14,226 | Implemented |
OK0639 # 05 Y:2002 | 05 | 2002 | INSTALL SET-BACK TIMERS | $6,583 | $160 | Implemented |
OK0639 # 04 Y:2002 | 04 | 2002 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $1,338 | $4,126 | Not Implemented |
OK0639 # 02 Y:2002 | 02 | 2002 | IMPROVE SPACE COMFORT CONDITIONING | $42,500 | $3,150 | Not Implemented |
OK0639 # 01 Y:2002 | 01 | 2002 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $5,500 | $0 | Implemented |
OK0501 # 07 Y:1996 | 07 | 1996 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $340,445 | $198,500 | Not Implemented |
OK0501 # 06 Y:1996 | 06 | 1996 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,678 | $10,815 | Not Implemented |
OK0501 # 05 Y:1996 | 05 | 1996 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,117 | $1,957 | Not Implemented |
OK0501 # 01 Y:1996 | 01 | 1996 | UPGRADE CONTROLS ON COMPRESSORS | $7,290 | $2,800 | Implemented |
OK0501 # 02 Y:1996 | 02 | 1996 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $10,133 | $0 | Implemented |
OK0501 # 03 Y:1996 | 03 | 1996 | USE MINIMUM STEAM OPERATING PRESSURE | $3,659 | $0 | Implemented |
OK0501 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $816 | $2,570 | Not Implemented |
OK0388 # 03 Y:1992 | 03 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $482 | $1,424 | Not Implemented |
OK0388 # 04 Y:1992 | 04 | 1992 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $231 | $0 | Not Implemented |
OK0388 # 05 Y:1992 | 05 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $297 | $0 | Implemented |
OK0388 # 02 Y:1992 | 02 | 1992 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,508 | $11,034 | Implemented |
OK0388 # 01 Y:1992 | 01 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,461 | $1,798 | Implemented |
OK0383 # 05 Y:1992 | 05 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,966 | $0 | Implemented |
OK0383 # 04 Y:1992 | 04 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $224 | $236 | Implemented |
OK0383 # 02 Y:1992 | 02 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,589 | $1,399 | Implemented |