Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
21
matching recommendationsSIC | 3699 | Electrical Equipment & Supplies, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0311 # 06 Y:2002 | 06 | 2002 | RECYCLE FLUORESCENT LAMPS | $10,412 | $1,895 | Not Implemented |
UF0311 # 05 Y:2002 | 05 | 2002 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $31,940 | $189,000 | Not Implemented |
UF0311 # 04 Y:2002 | 04 | 2002 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $15,812 | $20,000 | Implemented |
UF0311 # 03 Y:2002 | 03 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,246 | $0 | Not Implemented |
UF0311 # 02 Y:2002 | 02 | 2002 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $20,300 | $1,640 | Implemented |
UF0311 # 01 Y:2002 | 01 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $27,935 | $119,640 | Not Implemented |
UF0300 # 03 Y:2002 | 03 | 2002 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $152,665 | $117,000 | n/a |
UF0300 # 07 Y:2002 | 07 | 2002 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $931 | $1,895 | n/a |
UF0300 # 06 Y:2002 | 06 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $106,637 | $10,907 | n/a |
UF0300 # 05 Y:2002 | 05 | 2002 | INSTALL OCCUPANCY SENSORS | $1,960 | $518 | n/a |
UF0300 # 04 Y:2002 | 04 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,740 | $290 | n/a |
UF0300 # 02 Y:2002 | 02 | 2002 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,536 | $0 | n/a |
UF0300 # 01 Y:2002 | 01 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $13,724 | $25,919 | n/a |
UF0283 # 01 Y:2001 | 01 | 2001 | INSTALL OCCUPANCY SENSORS | $1,347 | $2,485 | Implemented |
UF0283 # 08 Y:2001 | 08 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,806 | $0 | Implemented |
UF0283 # 07 Y:2001 | 07 | 2001 | DEMOLISH OLD BUILDING TO REDUCE TAX AND INSURANCE BILLS | $59,856 | $420,000 | Not Implemented |
UF0283 # 06 Y:2001 | 06 | 2001 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $720 | $0 | Not Implemented |
UF0283 # 05 Y:2001 | 05 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,592 | $1,440 | Implemented |
UF0283 # 04 Y:2001 | 04 | 2001 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $82,496 | $400 | Not Implemented |
UF0283 # 03 Y:2001 | 03 | 2001 | STORE HEATED/ COOLED WATER FOR USE DURING PEAK DEMAND PERIODS | $9,278 | $76,200 | Not Implemented |
UF0283 # 02 Y:2001 | 02 | 2001 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $13,166 | $9,333 | Not Implemented |