Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,523
matching recommendationsSIC | 37 | Transportation Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0499 # 04 Y:2015 | 04 | 2015 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $4,878 | $1,000 | Implemented |
WV0499 # 05 Y:2015 | 05 | 2015 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,187 | $0 | Not Implemented |
WV0499 # 06 Y:2015 | 06 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,695 | $3,343 | Implemented |
WV0499 # 07 Y:2015 | 07 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,825 | $20 | Implemented |
WV0499 # 08 Y:2015 | 08 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,734 | $5,450 | Not Implemented |
WV0499 # 09 Y:2015 | 09 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $792 | $0 | Implemented |
WV0499 # 10 Y:2015 | 10 | 2015 | DEVELOP A REPAIR/REPLACE POLICY | $781 | $569 | Implemented |
IP0034 # 01 Y:2015 | 01 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,454 | $0 | Implemented |
IP0034 # 02 Y:2015 | 02 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,112 | $0 | Implemented |
IP0034 # 03 Y:2015 | 03 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $111 | $0 | Not Implemented |
IP0034 # 04 Y:2015 | 04 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,686 | $636 | Not Implemented |
IP0034 # 05 Y:2015 | 05 | 2015 | INSULATE BARE EQUIPMENT | $974 | $104 | Not Implemented |
IP0034 # 06 Y:2015 | 06 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,451 | $845 | Not Implemented |
IP0034 # 07 Y:2015 | 07 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $41,425 | $89,660 | Not Implemented |
MA0740 # 01 Y:2015 | 01 | 2015 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $18,853 | $200 | Implemented |
MA0740 # 02 Y:2015 | 02 | 2015 | INSTALL / REPAIR INSULATION ON STEAM LINES | $5,057 | $4,200 | Implemented |
MA0740 # 03 Y:2015 | 03 | 2015 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $4,672 | $11,200 | Implemented |
MA0740 # 04 Y:2015 | 04 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,745 | $6,695 | Implemented |
MA0740 # 05 Y:2015 | 05 | 2015 | REDUCE VENTILATION AIR | $3,084 | $2,450 | Implemented |
MA0740 # 06 Y:2015 | 06 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,904 | $1,425 | Implemented |
MA0740 # 07 Y:2015 | 07 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,652 | $5,375 | Not Implemented |
MA0740 # 08 Y:2015 | 08 | 2015 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $1,775 | $2,010 | Implemented |
MA0740 # 09 Y:2015 | 09 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $426 | $500 | Implemented |
MZ0161 # 01 Y:2014 | 01 | 2014 | UPGRADE CONTROLS ON COMPRESSORS | $54,484 | $150,000 | Not Implemented |
MZ0161 # 02 Y:2014 | 02 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,393 | $11,000 | Not Implemented |