Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
471
matching recommendationsSIC | 37 | Transportation Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ND0347 # 04 Y:2000 | 04 | 2000 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $115 | $0 | Implemented |
ND0347 # 05 Y:2000 | 05 | 2000 | DEVELOP A REPAIR/REPLACE POLICY | $360 | $843 | Not Implemented |
ND0347 # 06 Y:2000 | 06 | 2000 | USE OPTIMUM TEMPERATURE | $10 | $8 | Implemented |
ND0347 # 07 Y:2000 | 07 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $236 | $900 | Implemented |
ND0347 # 08 Y:2000 | 08 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $79 | $340 | Not Implemented |
ND0306 # 01 Y:1998 | 01 | 1998 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $4,789 | $250 | Not Implemented |
ND0306 # 02 Y:1998 | 02 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,135 | $200 | Not Implemented |
ND0306 # 03 Y:1998 | 03 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,628 | $840 | Implemented |
ND0306 # 04 Y:1998 | 04 | 1998 | COMBINE UTILITY METERS | $8,974 | $9,000 | Not Implemented |
ND0306 # 05 Y:1998 | 05 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $868 | $1,000 | Not Implemented |
ND0306 # 06 Y:1998 | 06 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $923 | $715 | Not Implemented |
ND0306 # 07 Y:1998 | 07 | 1998 | DEVELOP A REPAIR/REPLACE POLICY | $1,416 | $3,847 | Not Implemented |
ND0306 # 08 Y:1998 | 08 | 1998 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $488 | $850 | Not Implemented |
ND0306 # 09 Y:1998 | 09 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $34 | $70 | Implemented |
ND0306 # 10 Y:1998 | 10 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,626 | $7,750 | Not Implemented |
ND0306 # 11 Y:1998 | 11 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,649 | $16,479 | Not Implemented |
ND0306 # 12 Y:1998 | 12 | 1998 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $8,560 | $58,000 | Implemented |
ND0306 # 13 Y:1998 | 13 | 1998 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $11,316 | $250 | Not Implemented |
ND0306 # 14 Y:1998 | 14 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $84 | $70 | Implemented |
ND0306 # 15 Y:1998 | 15 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $443 | $298 | Not Implemented |
ND0306 # 16 Y:1998 | 16 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $340 | $214 | Not Implemented |
ND0306 # 17 Y:1998 | 17 | 1998 | USE OPTIMUM TEMPERATURE | $103 | $60 | Not Implemented |
ND0306 # 18 Y:1998 | 18 | 1998 | OPTIMIZE PLANT POWER FACTOR | $460 | $460 | Not Implemented |
ND0306 # 19 Y:1998 | 19 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $981 | $1,400 | Not Implemented |
ND0306 # 20 Y:1998 | 20 | 1998 | DEVELOP A REPAIR/REPLACE POLICY | $18,807 | $12,749 | Not Implemented |