Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,523
matching recommendationsSIC | 37 | Transportation Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IP0005 # 05 Y:2012 | 05 | 2012 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $16,542 | $37,000 | Not Implemented |
TT0098 # 01 Y:2012 | 01 | 2012 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $1,053 | $1,116 | Implemented |
TT0098 # 02 Y:2012 | 02 | 2012 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,222 | $2,320 | Implemented |
TT0098 # 03 Y:2012 | 03 | 2012 | DE-ENERGIZE EXCESS TRANSFORMER CAPACITY | $1,898 | $5,525 | Not Implemented |
TT0098 # 04 Y:2012 | 04 | 2012 | USE SOLAR HEAT TO HEAT MAKE-UP AIR | $5,814 | $43,695 | Not Implemented |
TT0098 # 05 Y:2012 | 05 | 2012 | REPAIR AND ELIMINATE STEAM LEAKS | $7,381 | $980 | Implemented |
OK0832 # 01 Y:2012 | 01 | 2012 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,902 | $7,700 | Not Implemented |
OK0832 # 02 Y:2012 | 02 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $955 | $1,288 | Not Implemented |
OK0832 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $995 | $6,375 | Not Implemented |
OK0832 # 04 Y:2012 | 04 | 2012 | INSTALL OCCUPANCY SENSORS | $655 | $4,180 | Not Implemented |
OK0832 # 05 Y:2012 | 05 | 2012 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $18,428 | $7,200 | Not Implemented |
OK0832 # 06 Y:2012 | 06 | 2012 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $7,382 | $34,962 | Not Implemented |
OK0832 # 07 Y:2012 | 07 | 2012 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $6,074 | $29,738 | Not Implemented |
OK0832 # 08 Y:2012 | 08 | 2012 | INSTALL SET-BACK TIMERS | $2,158 | $185 | Not Implemented |
OK0832 # 09 Y:2012 | 09 | 2012 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $2,579 | $1,170 | Implemented |
OK0832 # 10 Y:2012 | 10 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,669 | $696 | Not Implemented |
OK0832 # 11 Y:2012 | 11 | 2012 | OPTIMIZE PLANT POWER FACTOR | $1,632 | $8,864 | Not Implemented |
TT0097 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $62,026 | $78,780 | Implemented |
TT0097 # 02 Y:2012 | 02 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $25,306 | $19,700 | Not Implemented |
TT0097 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $63,167 | $106,204 | Implemented |
BS0007 # 01 Y:2012 | 01 | 2012 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $1,790 | $4,911 | Not Implemented |
BS0007 # 02 Y:2012 | 02 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,760 | $649 | Implemented |
BS0007 # 03 Y:2012 | 03 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $98 | $0 | Not Implemented |
BS0007 # 04 Y:2012 | 04 | 2012 | INSTALL OCCUPANCY SENSORS | $186 | $300 | Not Implemented |
BS0007 # 05 Y:2012 | 05 | 2012 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,845 | $6,260 | Not Implemented |