Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,799
matching recommendationsSIC | 37 | Transportation Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0680 # 12 Y:2003 | 12 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,465 | $900 | Implemented |
UD0680 # 13 Y:2003 | 13 | 2003 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,815 | $0 | Implemented |
UD0680 # 14 Y:2003 | 14 | 2003 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,717 | $0 | Not Implemented |
UD0680 # 15 Y:2003 | 15 | 2003 | DISCONNECT BALLASTS | $1,248 | $0 | Not Implemented |
UD0680 # 16 Y:2003 | 16 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,235 | $90 | Not Implemented |
UD0680 # 17 Y:2003 | 17 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,200 | $470 | Not Implemented |
UU0053 # 01 Y:2003 | 01 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,354 | $4,100 | Not Implemented |
UU0053 # 02 Y:2003 | 02 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $11,131 | $55 | Not Implemented |
UU0053 # 03 Y:2003 | 03 | 2003 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,710 | $2,000 | Not Implemented |
UU0053 # 04 Y:2003 | 04 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,112 | $70,635 | Not Implemented |
UU0053 # 05 Y:2003 | 05 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,869 | $2,340 | Implemented |
UU0053 # 06 Y:2003 | 06 | 2003 | INSTALL TURBULATORS | $2,610 | $1,572 | Not Implemented |
UF0330 # 01 Y:2003 | 01 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,935 | $0 | Not Implemented |
UF0330 # 02 Y:2003 | 02 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,321 | $0 | Not Implemented |
UF0330 # 03 Y:2003 | 03 | 2003 | DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING | $1,174 | $0 | Implemented |
UF0330 # 04 Y:2003 | 04 | 2003 | INSTALL AUTOMATIC PART STORAGE / RETREVAL SYSTEM | $4,992 | $974 | Not Implemented |
UF0330 # 05 Y:2003 | 05 | 2003 | INSTALL EQUIPMENT TO MOVE PRODUCT | $43,330 | $23,017 | Not Implemented |
UF0330 # 06 Y:2003 | 06 | 2003 | AUTOMATE FINISHING PROCESS | $132,990 | $300,000 | Not Implemented |
UU0051 # 01 Y:2003 | 01 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,232 | $0 | Not Implemented |
UU0051 # 02 Y:2003 | 02 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $744 | $340 | Not Implemented |
UU0051 # 03 Y:2003 | 03 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,845 | $961 | Not Implemented |
UU0051 # 04 Y:2003 | 04 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,130 | $11,800 | Not Implemented |
UU0051 # 05 Y:2003 | 05 | 2003 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $2,823 | $0 | Not Implemented |
UU0051 # 06 Y:2003 | 06 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,510 | $5,980 | Not Implemented |
UU0051 # 07 Y:2003 | 07 | 2003 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $2,270 | $8,450 | Not Implemented |