Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

845

matching recommendations
Reset
SIC 37 Transportation Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0320 # 04 Y:1990 04 1990 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,361 $3,000 Not Implemented
UD0274 # 01 Y:1989 01 1989 REDUCE VENTILATION AIR $8,923 $500 Implemented
UD0274 # 02 Y:1989 02 1989 INSTALL TIMERS AND/OR THERMOSTATS $3,754 $900 Implemented
UD0274 # 03 Y:1989 03 1989 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $11,724 $0 Implemented
UD0274 # 04 Y:1989 04 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $13,413 $32,500 Implemented
UD0274 # 05 Y:1989 05 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $482 $650 Implemented
UD0193 # 01 Y:1986 01 1986 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $52,010 $16,000 Not Implemented
UD0193 # 02 Y:1986 02 1986 INSTALL STORM WINDOWS AND DOORS $12,529 $16,200 Not Implemented
UD0193 # 03 Y:1986 03 1986 INSTALL SET-BACK TIMERS $1,589 $0 Implemented
UD0193 # 04 Y:1986 04 1986 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $3,168 $0 Implemented
UD0193 # 05 Y:1986 05 1986 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $9,134 $21,000 Implemented
UD0146 # 01 Y:1984 01 1984 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $1,620 $0 Implemented
UD0146 # 02 Y:1984 02 1984 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $598 $210 Implemented
UD0142 # 01 Y:1984 01 1984 REPLACE WATER COOLING ON PROCESSES WITH AIR COOLING $28,921 $935 Implemented
UD0142 # 02 Y:1984 02 1984 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $6,060 $10,000 Implemented
UD0142 # 03 Y:1984 03 1984 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,810 $384 Implemented
UD0139 # 01 Y:1984 01 1984 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $3,912 $510 Implemented
UD0139 # 02 Y:1984 02 1984 INSTALL TIMERS AND/OR THERMOSTATS $3,450 $62 Implemented
UD0139 # 03 Y:1984 03 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,083 $530 Implemented
UD0139 # 04 Y:1984 04 1984 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $4,318 $0 Implemented
UD0139 # 05 Y:1984 05 1984 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $7,736 $15,100 Implemented
UD0104 # 01 Y:1983 01 1983 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $39,300 $0 Implemented
UD0104 # 02 Y:1983 02 1983 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,527 $0 Implemented
UD0104 # 03 Y:1983 03 1983 INSTALL TIMERS AND/OR THERMOSTATS $10,180 $4,000 Implemented
UD0104 # 04 Y:1983 04 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,605 $1,592 Implemented