Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,376
matching recommendationsSIC | 371 | Motor Vehicles And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MO0201 # 11 Y:1997 | 11 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,174 | $922 | Implemented |
MO0201 # 12 Y:1997 | 12 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $623 | $1,346 | Implemented |
BD0082 # 01 Y:1997 | 01 | 1997 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,539 | $2,500 | Implemented |
BD0082 # 02 Y:1997 | 02 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,024 | $8,880 | Implemented |
BD0082 # 04 Y:1997 | 04 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $959 | $553 | Implemented |
BD0082 # 06 Y:1997 | 06 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $793 | $500 | Implemented |
BD0082 # 10 Y:1997 | 10 | 1997 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $20,759 | $1,800 | Implemented |
MO0197 # 01 Y:1997 | 01 | 1997 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $16,060 | $15,000 | Implemented |
MO0197 # 02 Y:1997 | 02 | 1997 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $9,288 | $7,500 | Implemented |
MO0197 # 03 Y:1997 | 03 | 1997 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $4,800 | $10,000 | Implemented |
MO0197 # 04 Y:1997 | 04 | 1997 | RECOVER AND REUSE WASTE MATERIAL | $13,642 | $0 | Implemented |
MO0197 # 05 Y:1997 | 05 | 1997 | IMPLEMENT A REGULAR MAINTENANCE PROGRAM TO REDUCE EMISSIONS FROM LEAKY VALVES AND PIPE FITTINGS | $1,052 | $3,000 | Implemented |
MO0197 # 06 Y:1997 | 06 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,247 | $4,192 | Implemented |
MO0197 # 07 Y:1997 | 07 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,358 | $1,718 | Implemented |
MO0197 # 08 Y:1997 | 08 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $303 | $0 | Implemented |
MO0197 # 09 Y:1997 | 09 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,128 | $337 | Implemented |
MO0197 # 10 Y:1997 | 10 | 1997 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $14,076 | $35,980 | Implemented |
TN0602 # 01 Y:1997 | 01 | 1997 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $333,410 | $0 | Implemented |
TN0602 # 02 Y:1997 | 02 | 1997 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $327,397 | $0 | Implemented |
TN0602 # 03 Y:1997 | 03 | 1997 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $83,573 | $108,500 | Implemented |
TN0602 # 04 Y:1997 | 04 | 1997 | USE RADIANT HEATER FOR SPOT HEATING | $96,084 | $35,020 | Implemented |
TN0602 # 05 Y:1997 | 05 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $16,339 | $3,000 | Implemented |
TN0602 # 06 Y:1997 | 06 | 1997 | ADD AREA LIGHTING SWITCHES | $11,208 | $13,340 | Implemented |
TN0602 # 07 Y:1997 | 07 | 1997 | INSTALL TIMERS AND/OR THERMOSTATS | $10,349 | $2,016 | Implemented |