Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,381
matching recommendationsSIC | 371 | Motor Vehicles And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0024 # 06 Y:1992 | 06 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,454 | $50 | Implemented |
IA0024 # 07 Y:1992 | 07 | 1992 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,218 | $1,218 | Implemented |
IA0024 # 08 Y:1992 | 08 | 1992 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $4,688 | $426 | Implemented |
TN0475 # 01 Y:1992 | 01 | 1992 | AIR CONDITION ONLY SPACE NECESSARY | $987 | $3,100 | Implemented |
TN0475 # 02 Y:1992 | 02 | 1992 | KEEP LAMPS AND REFLECTORS CLEAN | $781 | $2,524 | Implemented |
TN0475 # 03 Y:1992 | 03 | 1992 | IMPROVE LUBRICATION PRACTICES | $602 | $0 | Implemented |
TN0475 # 04 Y:1992 | 04 | 1992 | INSTALL SET-BACK TIMERS | $582 | $0 | Implemented |
TN0475 # 05 Y:1992 | 05 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $433 | $580 | Implemented |
TN0475 # 06 Y:1992 | 06 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $148 | $30 | Implemented |
TN0475 # 07 Y:1992 | 07 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $42 | $20 | Implemented |
UF0038 # 01 Y:1992 | 01 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,249 | $1,872 | Implemented |
UF0038 # 07 Y:1992 | 07 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $659 | $575 | Implemented |
UF0038 # 09 Y:1992 | 09 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,296 | $550 | Implemented |
UF0037 # 04 Y:1992 | 04 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,426 | $550 | Implemented |
UF0037 # 05 Y:1992 | 05 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,492 | $15,213 | Implemented |
UF0037 # 09 Y:1992 | 09 | 1992 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $289 | $1,100 | Implemented |
MO0063 # 03 Y:1992 | 03 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,732 | $1,000 | Implemented |
MO0063 # 04 Y:1992 | 04 | 1992 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,778 | $150 | Implemented |
MO0063 # 06 Y:1992 | 06 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $897 | $850 | Implemented |
MO0063 # 07 Y:1992 | 07 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,845 | $14,900 | Implemented |
MO0063 # 08 Y:1992 | 08 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $964 | $12,900 | Implemented |
MO0058 # 04 Y:1992 | 04 | 1992 | INSTALL SET-BACK TIMERS | $1,712 | $1,400 | Implemented |
MO0058 # 08 Y:1992 | 08 | 1992 | IMPROVE LUBRICATION PRACTICES | $828 | $240 | Implemented |
TN0464 # 01 Y:1992 | 01 | 1992 | KEEP LAMPS AND REFLECTORS CLEAN | $8,302 | $23,381 | Implemented |
TN0464 # 02 Y:1992 | 02 | 1992 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $963 | $1,872 | Implemented |