IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,374

matching recommendations
Reset
SIC 371 Motor Vehicles And Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
ND0280 # 08 Y:1997 08 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $606 $1,566 Implemented
ND0280 # 09 Y:1997 09 1997 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $948 $1,500 Not Implemented
ND0280 # 10 Y:1997 10 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $745 $1,160 Not Implemented
ND0280 # 11 Y:1997 11 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $420 $300 Not Implemented
ND0280 # 12 Y:1997 12 1997 INSTALL OCCUPANCY SENSORS $268 $200 Not Implemented
ND0280 # 13 Y:1997 13 1997 CONTRACT A WOOD PALLET RECYCLING COMPANY $90 $0 Implemented
ND0280 # 14 Y:1997 14 1997 TURN OFF EQUIPMENT WHEN NOT IN USE $20 $50 Not Implemented
OK0529 # 01 Y:1997 01 1997 SCHEDULE DELIVERIES ACCORDING TO DEMAND $37,800 $20,000 Not Implemented
OK0529 # 02 Y:1997 02 1997 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $7,974 $7,000 Not Implemented
OK0529 # 03 Y:1997 03 1997 USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS $6,792 $22,365 Not Implemented
OK0529 # 04 Y:1997 04 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,030 $4,595 Implemented
OK0529 # 05 Y:1997 05 1997 REDUCE VENTILATION AIR $1,370 $5,600 Not Implemented
OK0529 # 06 Y:1997 06 1997 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE $770 $0 Not Implemented
OK0529 # 07 Y:1997 07 1997 RECOVER WASTE HEAT FROM EQUIPMENT $499 $1,086 Implemented
OK0529 # 08 Y:1997 08 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $207 $1,440 Implemented
KG0092 # 01 Y:1997 01 1997 AIR CONDITION ONLY SPACE NECESSARY $23,912 $4,700 n/a
KG0092 # 02 Y:1997 02 1997 INSTALL TIMERS AND/OR THERMOSTATS $11,331 $750 n/a
KG0092 # 03 Y:1997 03 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $11,307 $36,080 n/a
KG0092 # 04 Y:1997 04 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,310 $49,768 n/a
KG0092 # 05 Y:1997 05 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $7,741 $0 n/a
KG0092 # 06 Y:1997 06 1997 TURN OFF EQUIPMENT WHEN NOT IN USE $5,693 $0 n/a
KG0092 # 07 Y:1997 07 1997 INSULATE BARE EQUIPMENT $4,478 $519 n/a
KG0092 # 08 Y:1997 08 1997 MODERATE COOLING TOWER OUTLET TEMPERATURE $1,889 $60 n/a
KG0092 # 09 Y:1997 09 1997 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $912 $3,530 n/a
KG0092 # 10 Y:1997 10 1997 LOWER CEILING TO REDUCE CONDITIONED SPACE $6,730 $2,180 n/a