Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,374

matching recommendations
Reset
SIC 371 Motor Vehicles And Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
HO0126 # 04 Y:1996 04 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,573 $400 Implemented
HO0126 # 05 Y:1996 05 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,352 $180 Implemented
HO0126 # 06 Y:1996 06 1996 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $5,430 $0 Not Implemented
OK0486 # 01 Y:1996 01 1996 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $4,955 $5,951 Not Implemented
OK0486 # 02 Y:1996 02 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $5,401 $3,275 Implemented
OK0486 # 03 Y:1996 03 1996 IMPROVE LUBRICATION PRACTICES $4,213 $0 Not Implemented
OK0486 # 04 Y:1996 04 1996 UPGRADE CONTROLS ON COMPRESSORS $1,548 $5,600 Implemented
OK0486 # 05 Y:1996 05 1996 DISCONNECT BALLASTS $428 $1,060 Implemented
OK0486 # 06 Y:1996 06 1996 INSTALL / REPAIR INSULATION ON STEAM LINES $203 $757 Implemented
OK0486 # 07 Y:1996 07 1996 TREAT AND REUSE RINSE WATERS $17,249 $0 Not Implemented
CO0353 # 01 Y:1996 01 1996 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $92,720 $50,000 Implemented
CO0353 # 02 Y:1996 02 1996 REMOVE ROLLERS FROM THE MACHINES AND CLEAN IN A CLOSED SOLVENT CLEANER $24,450 $4,000 Implemented
CO0353 # 03 Y:1996 03 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,709 $16,548 Not Implemented
CO0353 # 04 Y:1996 04 1996 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $6,550 $56,160 Implemented
CO0353 # 05 Y:1996 05 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,020 $700 Implemented
CO0353 # 06 Y:1996 06 1996 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES $1,582 $3,680 Implemented
CO0353 # 07 Y:1996 07 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $990 $220 Implemented
CO0353 # 08 Y:1996 08 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $82 $53 Implemented
CO0354 # 01 Y:1996 01 1996 DISTILL CONTAMINATED SOLVENTS FOR REUSE $6,620 $12,550 Not Implemented
CO0354 # 02 Y:1996 02 1996 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $10,060 $47,840 Implemented
CO0354 # 03 Y:1996 03 1996 RECOVER WASTE HEAT FROM EQUIPMENT $1,640 $1,310 Not Implemented
CO0354 # 04 Y:1996 04 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $590 $1,065 Not Implemented
CO0354 # 05 Y:1996 05 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $510 $140 Implemented
CO0354 # 06 Y:1996 06 1996 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES $190 $0 Not Implemented
SD0139 # 01 Y:1996 01 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,319 $5,940 Implemented