Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
669
matching recommendationsSIC | 371 | Motor Vehicles And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0783 # 02 Y:2008 | 02 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $25,926 | $27,004 | Not Implemented |
UD0783 # 03 Y:2008 | 03 | 2008 | INSULATE BARE EQUIPMENT | $23,572 | $65,625 | Not Implemented |
UD0783 # 04 Y:2008 | 04 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $15,545 | $10,000 | Not Implemented |
UD0783 # 05 Y:2008 | 05 | 2008 | INSTALL OCCUPANCY SENSORS | $7,231 | $7,200 | Not Implemented |
UD0783 # 06 Y:2008 | 06 | 2008 | INSTALL SKYLIGHTS | $6,996 | $40,770 | Not Implemented |
UD0783 # 07 Y:2008 | 07 | 2008 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $5,745 | $0 | Not Implemented |
UD0783 # 08 Y:2008 | 08 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,324 | $0 | Not Implemented |
UD0783 # 09 Y:2008 | 09 | 2008 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $3,818 | $5,000 | Not Implemented |
UD0783 # 10 Y:2008 | 10 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,826 | $0 | Not Implemented |
UD0783 # 11 Y:2008 | 11 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,659 | $600 | Not Implemented |
UD0783 # 12 Y:2008 | 12 | 2008 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $1,581 | $500 | Not Implemented |
UD0783 # 13 Y:2008 | 13 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $970 | $1,000 | Not Implemented |
UD0783 # 14 Y:2008 | 14 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $844 | $500 | Not Implemented |
UD0783 # 15 Y:2008 | 15 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $837 | $400 | Not Implemented |
UD0737 # 01 Y:2006 | 01 | 2006 | ELIMINATE/REDUCE AN OPERATION | $448,000 | $-70,000 | Implemented |
UD0737 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,868 | $3,600 | Not Implemented |
UD0737 # 03 Y:2006 | 03 | 2006 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $9,201 | $0 | Not Implemented |
UD0737 # 04 Y:2006 | 04 | 2006 | UPGRADE CONTROLS ON COMPRESSORS | $7,933 | $1,436 | Not Implemented |
UD0737 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,592 | $15,876 | Not Implemented |
UD0737 # 06 Y:2006 | 06 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,404 | $0 | Not Implemented |
UD0737 # 07 Y:2006 | 07 | 2006 | SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING | $3,177 | $387 | Not Implemented |
UD0737 # 08 Y:2006 | 08 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,238 | $6,552 | Implemented |
UD0737 # 09 Y:2006 | 09 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,074 | $0 | Not Implemented |
UD0737 # 10 Y:2006 | 10 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,120 | $0 | Not Implemented |
UD0737 # 11 Y:2006 | 11 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $419 | $1,968 | Not Implemented |