Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
38
matching recommendationsSIC | 371 | Motor Vehicles And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BS0095 # 03 Y:2017 | 03 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,935 | $15,234 | Not Implemented |
BS0095 # 04 Y:2017 | 04 | 2017 | OPTIMIZE PLANT POWER FACTOR | $9,156 | $20,491 | Not Implemented |
BS0095 # 05 Y:2017 | 05 | 2017 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,362 | $1,171 | Not Implemented |
BS0095 # 06 Y:2017 | 06 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,327 | $128 | Implemented |
BS0095 # 07 Y:2017 | 07 | 2017 | UPGRADE CONTROLS ON COMPRESSORS | $9,891 | $13,498 | Not Implemented |
BS0095 # 08 Y:2017 | 08 | 2017 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $10,520 | $21,040 | Not Implemented |
BS0095 # 01 Y:2017 | 01 | 2017 | TURN OFF EQUIPMENT WHEN NOT IN USE | $9,634 | $1,202 | Implemented |
UU0061 # 06 Y:2004 | 06 | 2004 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $351 | $432 | Implemented |
UU0061 # 05 Y:2004 | 05 | 2004 | CONTRACT OUT MAINTENANCE | $15,000 | $2,000 | Not Implemented |
UU0061 # 04 Y:2004 | 04 | 2004 | INSTALL REDUNDANT EQUIPMENT TO AVOID LOSSES CAUSED BY EQUIPMENT FAILURE AND ROUTINE MAINTENANCE | $18,030 | $11,000 | Not Implemented |
UU0061 # 03 Y:2004 | 03 | 2004 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $274 | $0 | Implemented |
UU0061 # 02 Y:2004 | 02 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $267 | $1,000 | Not Implemented |
UU0061 # 01 Y:2004 | 01 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,895 | $18,633 | Not Implemented |