IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

133

matching recommendations
Reset
SIC 371 Motor Vehicles And Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MI0019 # 04 Y:2001 04 2001 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT $2,290 $2,530 n/a
MI0019 # 05 Y:2001 05 2001 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $8,266 $14,000 n/a
MI0019 # 06 Y:2001 06 2001 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $9,991 $288 n/a
MI0013 # 01 Y:2001 01 2001 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS $1,255 $710 Not Implemented
MI0013 # 02 Y:2001 02 2001 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $114,000 $32,515 Not Implemented
MI0013 # 03 Y:2001 03 2001 UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS $3,000 $5,000 Not Implemented
MI0013 # 04 Y:2001 04 2001 MODIFY STORAGE SPACE TO AVOID RENTAL OF A WAREHOUSE $6,641 $1,050 Not Implemented
MI0013 # 05 Y:2001 05 2001 INSTALL SPECTRAL REFLECTORS / DELAMP $3,176 $4,500 Not Implemented
MI0013 # 06 Y:2001 06 2001 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $9,000 $680 Not Implemented
MI0013 # 07 Y:2001 07 2001 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $2,791 $15 Not Implemented
UF0131 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,967 $13,352 Implemented
UF0131 # 02 Y:1995 02 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,319 $204 Not Implemented
UF0131 # 03 Y:1995 03 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,115 $14,659 Implemented
UF0131 # 04 Y:1995 04 1995 INSTALL OCCUPANCY SENSORS $677 $1,152 Not Implemented
UF0131 # 05 Y:1995 05 1995 DISCONNECT BALLASTS $553 $1,400 Not Implemented
UF0131 # 06 Y:1995 06 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,001 $1,116 Not Implemented
UF0131 # 07 Y:1995 07 1995 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $8,226 $11,400 Not Implemented
UF0131 # 08 Y:1995 08 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $845 $350 Implemented
UF0131 # 09 Y:1995 09 1995 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $110,283 $250,000 Not Implemented
UF0131 # 10 Y:1995 10 1995 USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME $85,495 $8,000 Implemented
UF0097 # 01 Y:1994 01 1994 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $2,917 $0 Not Implemented
UF0097 # 02 Y:1994 02 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,389 $4,359 Not Implemented
UF0097 # 03 Y:1994 03 1994 INSTALL SPECTRAL REFLECTORS / DELAMP $621 $888 Not Implemented
UF0097 # 04 Y:1994 04 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,231 $17,559 Implemented
UF0097 # 05 Y:1994 05 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $873 $3,458 Not Implemented