Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
106
matching recommendationsSIC | 371 | Motor Vehicles And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0522 # 02 Y:2006 | 02 | 2006 | IMPROVE SPACE COMFORT CONDITIONING | $14,000 | $3,000 | Implemented |
WI0522 # 03 Y:2006 | 03 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $12,607 | $2,000 | Implemented |
WI0522 # 04 Y:2006 | 04 | 2006 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $7,457 | $3,000 | Not Implemented |
WI0522 # 05 Y:2006 | 05 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $6,685 | $1,920 | Implemented |
WI0522 # 06 Y:2006 | 06 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,544 | $0 | Implemented |
WI0522 # 07 Y:2006 | 07 | 2006 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $4,560 | $12,105 | Not Implemented |
WI0487 # 01 Y:2005 | 01 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,912 | $11,200 | Implemented |
WI0487 # 02 Y:2005 | 02 | 2005 | INSTALL SPECTRAL REFLECTORS / DELAMP | $933 | $0 | Implemented |
WI0487 # 03 Y:2005 | 03 | 2005 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $5,262 | $5,600 | Implemented |
WI0487 # 04 Y:2005 | 04 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,836 | $780 | Implemented |
WI0487 # 05 Y:2005 | 05 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $714 | $1,280 | Implemented |
WI0487 # 06 Y:2005 | 06 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $334 | $400 | Implemented |
WI0487 # 07 Y:2005 | 07 | 2005 | INSTALL TIMERS AND/OR THERMOSTATS | $1,350 | $1,200 | Implemented |
WI0487 # 08 Y:2005 | 08 | 2005 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,185 | $1,400 | Not Implemented |
WI0487 # 09 Y:2005 | 09 | 2005 | PAY BILLS ON TIME TO AVOID LATE FEES | $1,172 | $0 | Implemented |
WI0487 # 10 Y:2005 | 10 | 2005 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $1,165 | $3,000 | Not Implemented |
WI0487 # 11 Y:2005 | 11 | 2005 | COVER OPEN TANKS | $1,108 | $360 | Not Implemented |
WI0259 # 01 Y:1996 | 01 | 1996 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $24,500 | $25,000 | Not Implemented |
WI0259 # 02 Y:1996 | 02 | 1996 | USE REVERSE OSMOSIS TO CONCENTRATE MATERIAL | $19,300 | $35,025 | Implemented |
WI0259 # 03 Y:1996 | 03 | 1996 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $13,875 | $5,000 | Not Implemented |
WI0259 # 04 Y:1996 | 04 | 1996 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $4,744 | $0 | Implemented |
WI0259 # 05 Y:1996 | 05 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,392 | $960 | Not Implemented |
WI0259 # 06 Y:1996 | 06 | 1996 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,107 | $4,300 | Implemented |
WI0259 # 07 Y:1996 | 07 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,936 | $492 | Not Implemented |
WI0259 # 08 Y:1996 | 08 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $925 | $1,000 | Not Implemented |