Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,374
matching recommendationsSIC | 371 | Motor Vehicles And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0095 # 02 Y:2013 | 02 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,789 | $800 | Not Implemented |
UA0095 # 03 Y:2013 | 03 | 2013 | USE COLD WASTE WATER TO COOL CHILLER FEED WATER | $18,583 | $59,040 | Not Implemented |
UA0095 # 04 Y:2013 | 04 | 2013 | DISCONNECT BALLASTS | $573 | $324 | Not Implemented |
UA0095 # 05 Y:2013 | 05 | 2013 | INSTALL OCCUPANCY SENSORS | $562 | $1,759 | Not Implemented |
WM0020 # 01 Y:2013 | 01 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,644 | $813 | Implemented |
WM0020 # 02 Y:2013 | 02 | 2013 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $804 | $1,510 | Not Implemented |
WM0020 # 03 Y:2013 | 03 | 2013 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $5,990 | $0 | Implemented |
WM0020 # 04 Y:2013 | 04 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,607 | $4,693 | Implemented |
WM0020 # 05 Y:2013 | 05 | 2013 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $4,570 | $0 | Implemented |
WM0020 # 06 Y:2013 | 06 | 2013 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $2,955 | $0 | Implemented |
UD0872 # 01 Y:2013 | 01 | 2013 | OPTIMIZE PLANT POWER FACTOR | $10,877 | $5,000 | Implemented |
UD0872 # 02 Y:2013 | 02 | 2013 | DEVELOP A REPAIR/REPLACE POLICY | $17,313 | $23,026 | Implemented |
UD0872 # 03 Y:2013 | 03 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $994 | $0 | Implemented |
UD0872 # 04 Y:2013 | 04 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $142,557 | $165,900 | Not Implemented |
UD0872 # 05 Y:2013 | 05 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $26,335 | $15,900 | Not Implemented |
UD0872 # 06 Y:2013 | 06 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $33,247 | $3,000 | Implemented |
UD0872 # 07 Y:2013 | 07 | 2013 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $14,025 | $21,037 | Not Implemented |
UD0872 # 08 Y:2013 | 08 | 2013 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $13,506 | $0 | Not Implemented |
UD0872 # 09 Y:2013 | 09 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,452 | $5,725 | Not Implemented |
UD0872 # 10 Y:2013 | 10 | 2013 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $16,273 | $31,000 | Not Implemented |
UD0872 # 11 Y:2013 | 11 | 2013 | IMPROVE COMBUSTION CONTROL CAPABILITY | $4,252 | $2,000 | Implemented |
UD0872 # 12 Y:2013 | 12 | 2013 | ADJUST BURNERS FOR EFFICIENT OPERATION | $2,274 | $5,000 | Not Implemented |
UD0872 # 13 Y:2013 | 13 | 2013 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $538 | $1,000 | Implemented |
UD0872 # 14 Y:2013 | 14 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $20,883 | $41,766 | Not Implemented |
UD0872 # 15 Y:2013 | 15 | 2013 | INSTALL TIMERS AND/OR THERMOSTATS | $14,454 | $16,450 | Not Implemented |