Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
489
matching recommendationsSIC | 3711 | Motor Vehicles And Car Bodies |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0226 # 05 Y:2012 | 05 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,132 | $1,400 | Implemented |
MI0226 # 06 Y:2012 | 06 | 2012 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $4,409 | $80 | Implemented |
MI0226 # 07 Y:2012 | 07 | 2012 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $3,519 | $11,300 | Not Implemented |
MI0226 # 08 Y:2012 | 08 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,579 | $1,660 | Implemented |
MI0226 # 09 Y:2012 | 09 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,502 | $80 | Implemented |
MI0226 # 10 Y:2012 | 10 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $922 | $80 | Implemented |
MI0226 # 11 Y:2012 | 11 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $656 | $3,010 | Implemented |
SU0320 # 01 Y:2012 | 01 | 2012 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,185 | $0 | Not Implemented |
SU0320 # 02 Y:2012 | 02 | 2012 | REDUCE VENTILATION AIR | $7,403 | $5,019 | Not Implemented |
SU0320 # 03 Y:2012 | 03 | 2012 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $18,749 | $42,038 | Not Implemented |
SU0320 # 04 Y:2012 | 04 | 2012 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $391 | $1,332 | Not Implemented |
SU0320 # 05 Y:2012 | 05 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,671 | $37,046 | Not Implemented |
SU0320 # 06 Y:2012 | 06 | 2012 | MAKE A NEW BY-PRODUCT | $21,685 | $100,000 | Not Implemented |
SU0320 # 07 Y:2012 | 07 | 2012 | ELIMINATE/REDUCE AN OPERATION | $2,644 | $15,840 | Not Implemented |
UMS002 # 01 Y:2012 | 01 | 2012 | INSULATE BARE EQUIPMENT | $1,300 | $1,000 | Not Implemented |
UMS002 # 02 Y:2012 | 02 | 2012 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $67,000 | $50,000 | Not Implemented |
LE0327 # 01 Y:2011 | 01 | 2011 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $92,227 | $175,000 | Implemented |
LE0327 # 02 Y:2011 | 02 | 2011 | REPLACE BOILER | $91,620 | $240,000 | Not Implemented |
LE0327 # 03 Y:2011 | 03 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $61,378 | $125 | Implemented |
LE0327 # 04 Y:2011 | 04 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $42,335 | $94,400 | Not Implemented |
LE0327 # 05 Y:2011 | 05 | 2011 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $15,778 | $2,102 | Not Implemented |
LE0327 # 06 Y:2011 | 06 | 2011 | INSTALL OCCUPANCY SENSORS | $5,653 | $7,280 | Not Implemented |
LE0327 # 07 Y:2011 | 07 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,286 | $1,900 | Implemented |
LE0327 # 08 Y:2011 | 08 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $360 | $400 | Not Implemented |
DL0073 # 01 Y:2011 | 01 | 2011 | BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT | $904,000 | $2,850,000 | Not Implemented |