Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

26

matching recommendations
Reset
SIC 3713 Truck And Bus Bodies
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0968 # 05 Y:2023 05 2023 USE SOLAR HEAT TO MAKE ELECTRICTY $159,818 $4,611,930 Not Implemented
GT0968 # 04 Y:2023 04 2023 TURN OFF EQUIPMENT WHEN NOT IN USE $3,052 $3,250 Implemented
GT0968 # 03 Y:2023 03 2023 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $73,640 $23,680 Implemented
GT0968 # 02 Y:2023 02 2023 TURN OFF EQUIPMENT WHEN NOT IN USE $104,725 $13,000 Implemented
GT0968 # 01 Y:2023 01 2023 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $64,657 $1,850 Implemented
GT0862 # 07 Y:2009 07 2009 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,618 $11,925 Not Implemented
GT0862 # 06 Y:2009 06 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,517 $9,840 Not Implemented
GT0862 # 05 Y:2009 05 2009 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $325 $449 Not Implemented
GT0862 # 04 Y:2009 04 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $810 $500 Not Implemented
GT0862 # 03 Y:2009 03 2009 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $439 $0 Not Implemented
GT0862 # 02 Y:2009 02 2009 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $962 $0 Not Implemented
GT0862 # 01 Y:2009 01 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,845 $17,464 Not Implemented
GT0794 # 09 Y:2004 09 2004 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,609 $0 Implemented
GT0794 # 08 Y:2004 08 2004 RECOVER WASTE HEAT FROM EQUIPMENT $8,773 $4,900 Not Implemented
GT0794 # 07 Y:2004 07 2004 INSTALL TIMERS AND/OR THERMOSTATS $729 $1,500 Not Implemented
GT0794 # 06 Y:2004 06 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,490 $2,500 Implemented
GT0794 # 05 Y:2004 05 2004 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $5,022 $3,380 Not Implemented
GT0794 # 04 Y:2004 04 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,306 $2,046 Implemented
GT0794 # 03 Y:2004 03 2004 INSTALL OCCUPANCY SENSORS $595 $765 Not Implemented
GT0794 # 02 Y:2004 02 2004 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,785 $3,525 Not Implemented
GT0794 # 01 Y:2004 01 2004 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $15,414 $30,000 n/a
GT0455 # 01 Y:1991 01 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $77 $0 Not Implemented
GT0455 # 05 Y:1991 05 1991 INSTALL TIMERS AND/OR THERMOSTATS $1,249 $0 Not Implemented
GT0455 # 04 Y:1991 04 1991 AIR CONDITION ONLY SPACE NECESSARY $1,540 $930 Not Implemented
GT0455 # 03 Y:1991 03 1991 RECOVER WASTE HEAT FROM EQUIPMENT $1,230 $2,625 Not Implemented