Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

597

matching recommendations
Reset
SIC 3714 Motor Vehicle Parts And Accessories
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0680 # 01 Y:2003 01 2003 IMPROVE COMBUSTION CONTROL CAPABILITY $24,031 $500 Implemented
UD0680 # 02 Y:2003 02 2003 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $11,750 $1,460 Implemented
UD0680 # 03 Y:2003 03 2003 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $9,824 $2,160 Not Implemented
UD0680 # 04 Y:2003 04 2003 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $8,140 $0 Implemented
UD0680 # 05 Y:2003 05 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,243 $14,256 Implemented
UD0680 # 06 Y:2003 06 2003 IMPROVE COMBUSTION CONTROL CAPABILITY $6,819 $0 Not Implemented
UD0680 # 07 Y:2003 07 2003 ADD AREA LIGHTING SWITCHES $6,667 $0 Not Implemented
UD0680 # 08 Y:2003 08 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $4,115 $0 Not Implemented
UD0680 # 09 Y:2003 09 2003 OPTIMIZE PLANT POWER FACTOR $4,028 $5,000 Not Implemented
UD0680 # 10 Y:2003 10 2003 IMPROVE COMBUSTION CONTROL CAPABILITY $3,078 $0 Implemented
UD0680 # 11 Y:2003 11 2003 COVER OPEN TANKS $2,708 $1,375 Implemented
UD0680 # 12 Y:2003 12 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,465 $900 Implemented
UD0680 # 13 Y:2003 13 2003 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,815 $0 Implemented
UD0680 # 14 Y:2003 14 2003 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,717 $0 Not Implemented
UD0680 # 15 Y:2003 15 2003 DISCONNECT BALLASTS $1,248 $0 Not Implemented
UD0680 # 16 Y:2003 16 2003 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,235 $90 Not Implemented
UD0680 # 17 Y:2003 17 2003 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,200 $470 Not Implemented
UD0656 # 01 Y:2002 01 2002 ELIMINATE/REDUCE REDUNDANT INSPECTIONS $160,000 $0 Not Implemented
UD0656 # 02 Y:2002 02 2002 SCHEDULE DELIVERIES ACCORDING TO DEMAND $36,000 $0 Implemented
UD0656 # 03 Y:2002 03 2002 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS $24,000 $2,500 Not Implemented
UD0656 # 04 Y:2002 04 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,934 $1,390 Not Implemented
UD0656 # 05 Y:2002 05 2002 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,677 $1,680 Not Implemented
UD0656 # 06 Y:2002 06 2002 DISCONNECT BALLASTS $2,338 $110 Not Implemented
UD0656 # 07 Y:2002 07 2002 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,266 $3,422 Implemented
UD0656 # 08 Y:2002 08 2002 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $225 $80 Implemented