Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
91
matching recommendationsSIC | 3714 | Motor Vehicle Parts And Accessories |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0659 # 03 Y:1999 | 03 | 1999 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $6,520 | $10,300 | Not Implemented |
TN0659 # 04 Y:1999 | 04 | 1999 | PURCHASE APPROPRIATELY SIZED MATERIAL | $5,860 | $0 | Not Implemented |
TN0659 # 05 Y:1999 | 05 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,642 | $1,860 | Implemented |
TN0659 # 06 Y:1999 | 06 | 1999 | INSTALL SPECTRAL REFLECTORS / DELAMP | $1,890 | $3,060 | Not Implemented |
TN0659 # 07 Y:1999 | 07 | 1999 | INSULATE BARE EQUIPMENT | $590 | $131 | Not Implemented |
NC0125 # 05 Y:1997 | 05 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $1,480 | $4,200 | Not Implemented |
NC0125 # 04 Y:1997 | 04 | 1997 | INSTALL SKYLIGHTS | $7,876 | $40,250 | Not Implemented |
NC0125 # 03 Y:1997 | 03 | 1997 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $25,586 | $0 | Not Implemented |
NC0125 # 02 Y:1997 | 02 | 1997 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $7,740 | $1,600 | Not Implemented |
NC0125 # 01 Y:1997 | 01 | 1997 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $34,969 | $195,000 | Not Implemented |
NC0125 # 06 Y:1997 | 06 | 1997 | UTILIZE A CENTRAL COOLANT SYSTEM FOR CLEANING AND REUSE OF METAL WORKING FLUID | $129,253 | $33,480 | Implemented |
NC0026 # 01 Y:1994 | 01 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $972 | $210 | Implemented |
NC0026 # 02 Y:1994 | 02 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,139 | $1,646 | Implemented |
NC0026 # 03 Y:1994 | 03 | 1994 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $17,901 | $25,000 | Not Implemented |
NC0026 # 04 Y:1994 | 04 | 1994 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,373 | $1,500 | Not Implemented |
NC0026 # 05 Y:1994 | 05 | 1994 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,424 | $500 | Implemented |
NC0003 # 07 Y:1993 | 07 | 1993 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $307 | $650 | Implemented |
NC0003 # 06 Y:1993 | 06 | 1993 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $13,205 | $31,000 | Not Implemented |
NC0003 # 05 Y:1993 | 05 | 1993 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,594 | $6,000 | Implemented |
NC0003 # 04 Y:1993 | 04 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,844 | $1,000 | Implemented |
NC0003 # 03 Y:1993 | 03 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,625 | $300 | Implemented |
NC0003 # 02 Y:1993 | 02 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $648 | $360 | Implemented |
NC0003 # 01 Y:1993 | 01 | 1993 | USE PHOTOCELL CONTROLS | $381 | $159 | Implemented |
AT0099 # 03 Y:1988 | 03 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $359 | $0 | Implemented |
AT0099 # 01 Y:1988 | 01 | 1988 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $13,458 | $30,640 | Implemented |