Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
115
matching recommendationsSIC | 3714 | Motor Vehicle Parts And Accessories |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0591 # 02 Y:2000 | 02 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,477 | $4,942 | Implemented |
OK0591 # 03 Y:2000 | 03 | 2000 | INSTALL OCCUPANCY SENSORS | $875 | $136 | Not Implemented |
OK0591 # 04 Y:2000 | 04 | 2000 | BURN A LESS EXPENSIVE GRADE OF FUEL | $9,042 | $230,000 | Not Implemented |
OK0591 # 05 Y:2000 | 05 | 2000 | USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS | $181,048 | $59,400 | Not Implemented |
OK0591 # 06 Y:2000 | 06 | 2000 | OPTIMIZE LOT SIZES TO REDUCE INVENTORY CARRYING COSTS | $21,407 | $30,000 | Not Implemented |
OK0486 # 01 Y:1996 | 01 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,955 | $5,951 | Not Implemented |
OK0486 # 02 Y:1996 | 02 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,401 | $3,275 | Implemented |
OK0486 # 03 Y:1996 | 03 | 1996 | IMPROVE LUBRICATION PRACTICES | $4,213 | $0 | Not Implemented |
OK0486 # 04 Y:1996 | 04 | 1996 | UPGRADE CONTROLS ON COMPRESSORS | $1,548 | $5,600 | Implemented |
OK0486 # 05 Y:1996 | 05 | 1996 | DISCONNECT BALLASTS | $428 | $1,060 | Implemented |
OK0486 # 06 Y:1996 | 06 | 1996 | INSTALL / REPAIR INSULATION ON STEAM LINES | $203 | $757 | Implemented |
OK0486 # 07 Y:1996 | 07 | 1996 | TREAT AND REUSE RINSE WATERS | $17,249 | $0 | Not Implemented |
OK0429 # 01 Y:1994 | 01 | 1994 | LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE | $1,839 | $2,500 | Implemented |
OK0429 # 02 Y:1994 | 02 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,730 | $1,600 | Implemented |
OK0429 # 03 Y:1994 | 03 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,310 | $0 | Implemented |
OK0429 # 04 Y:1994 | 04 | 1994 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $638 | $0 | Implemented |
OK0429 # 05 Y:1994 | 05 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $711 | $2,806 | Not Implemented |
OK0409 # 01 Y:1993 | 01 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,933 | $15,898 | Implemented |
OK0409 # 02 Y:1993 | 02 | 1993 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $584 | $0 | Implemented |
OK0409 # 03 Y:1993 | 03 | 1993 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $560 | $0 | Not Implemented |
OK0409 # 04 Y:1993 | 04 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $366 | $0 | Implemented |
OK0409 # 05 Y:1993 | 05 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $123 | $0 | Not Implemented |
OK0409 # 06 Y:1993 | 06 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $102 | $304 | Implemented |
OK0337 # 01 Y:1991 | 01 | 1991 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $59,130 | $29,025 | Implemented |
OK0337 # 02 Y:1991 | 02 | 1991 | INSULATE BARE EQUIPMENT | $24,414 | $1,184 | Implemented |