IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

287

matching recommendations
Reset
SIC 3714 Motor Vehicle Parts And Accessories
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MS0200 # 06 Y:2002 06 2002 DISCONNECT BALLASTS $146 $248 Not Implemented
MS0200 # 07 Y:2002 07 2002 INSTALL TIMERS AND/OR THERMOSTATS $135 $236 Not Implemented
TN0602 # 01 Y:1997 01 1997 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $333,410 $0 Implemented
TN0602 # 02 Y:1997 02 1997 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS $327,397 $0 Implemented
TN0602 # 03 Y:1997 03 1997 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $83,573 $108,500 Implemented
TN0602 # 04 Y:1997 04 1997 USE RADIANT HEATER FOR SPOT HEATING $96,084 $35,020 Implemented
TN0602 # 05 Y:1997 05 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $16,339 $3,000 Implemented
TN0602 # 06 Y:1997 06 1997 ADD AREA LIGHTING SWITCHES $11,208 $13,340 Implemented
TN0602 # 07 Y:1997 07 1997 INSTALL TIMERS AND/OR THERMOSTATS $10,349 $2,016 Implemented
TN0602 # 08 Y:1997 08 1997 REUSE / RECYCLE/ SELL PAPER PRODUCTS $3,540 $8,288 Implemented
TN0597 # 01 Y:1997 01 1997 RESCHEDULE BREAKS TO ALLOW FOR CONTINUOUS PRODUCTION $420,000 $0 Implemented
TN0597 # 02 Y:1997 02 1997 ELIMINATE THIRD SHIFT $35,200 $116,600 Not Implemented
TN0597 # 03 Y:1997 03 1997 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $10,210 $0 Implemented
TN0597 # 04 Y:1997 04 1997 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $4,865 $0 Implemented
TN0597 # 05 Y:1997 05 1997 USE A RAG RECYCLE SERVICE $3,800 $0 Not Implemented
TN0597 # 06 Y:1997 06 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,710 $2,000 Implemented
TN0597 # 07 Y:1997 07 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,180 $800 Implemented
TN0597 # 08 Y:1997 08 1997 INSTALL TIMERS AND/OR THERMOSTATS $1,830 $0 Implemented
TN0597 # 09 Y:1997 09 1997 MODIFY MATERIAL APPLICATION METHODS $1,560 $4,400 Implemented
TN0597 # 10 Y:1997 10 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $640 $460 Implemented
TN0586 # 01 Y:1996 01 1996 REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS $50,410 $15,300 Not Implemented
TN0586 # 02 Y:1996 02 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $39,080 $7,880 Implemented
TN0586 # 03 Y:1996 03 1996 USE EVAPORATION TO CONCENTRATE MATERIAL $32,200 $30,600 Not Implemented
TN0586 # 04 Y:1996 04 1996 TREAT AND REUSE RINSE WATERS $29,935 $66,740 Not Implemented
TN0586 # 05 Y:1996 05 1996 OPTIMIZE PLANT POWER FACTOR $25,125 $60,800 Not Implemented