Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

32

matching recommendations
Reset
SIC 3714 Motor Vehicle Parts And Accessories
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TT0278 # 03 Y:2022 03 2022 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $12,152 $1,500 Implemented
TT0278 # 04 Y:2022 04 2022 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $5,912 $18,000 Implemented
TT0278 # 01 Y:2022 01 2022 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $24,020 $107,478 Implemented
TT0278 # 07 Y:2022 07 2022 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT $3,425 $0 Implemented
TT0278 # 08 Y:2022 08 2022 SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING $2,362 $2,736 Implemented
MS0342 # 04 Y:2009 04 2009 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $3,113 $0 Implemented
MS0342 # 06 Y:2009 06 2009 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $282 $0 Implemented
MS0342 # 03 Y:2009 03 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,780 $462 Implemented
MS0342 # 02 Y:2009 02 2009 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $8,753 $0 Implemented
MS0342 # 01 Y:2009 01 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $35,269 $61,142 Implemented
MS0339 # 01 Y:2009 01 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $21,229 $26,338 Implemented
MS0339 # 02 Y:2009 02 2009 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $3,499 $0 Implemented
MS0339 # 03 Y:2009 03 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,942 $378 Implemented
MS0339 # 04 Y:2009 04 2009 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,997 $0 Implemented
MS0339 # 06 Y:2009 06 2009 TURN OFF EQUIPMENT WHEN NOT IN USE $1,334 $0 Implemented
MS0283 # 03 Y:2005 03 2005 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $18,008 $50,375 Implemented
MS0283 # 04 Y:2005 04 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,338 $247 Implemented
MS0141 # 01 Y:1999 01 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $23,874 $806 Implemented
MS0141 # 02 Y:1999 02 1999 TURN OFF EQUIPMENT WHEN NOT IN USE $4,514 $99 Implemented
MS0116 # 05 Y:1998 05 1998 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,206 $1,478 Implemented
MS0116 # 06 Y:1998 06 1998 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $271 $549 Implemented
MS0116 # 09 Y:1998 09 1998 $20,640 $3,915 Implemented
MS0116 # 04 Y:1998 04 1998 USE DIRECT AIR SUPPLY TO EXHAUST HOODS $2,024 $1,688 Implemented
MS0116 # 02 Y:1998 02 1998 RECOVER WASTE HEAT FROM EQUIPMENT $4,475 $2,965 Implemented
MS0116 # 01 Y:1998 01 1998 INSTALL TIMERS AND/OR THERMOSTATS $2,591 $1,650 Implemented