Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
55
matching recommendationsSIC | 372 | Aircraft And Parts |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0360 # 10 Y:1999 | 10 | 1999 | INSTALL OCCUPANCY SENSORS | $2,640 | $5,800 | Implemented |
WI0360 # 08 Y:1999 | 08 | 1999 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $5,510 | $400 | Implemented |
WI0360 # 07 Y:1999 | 07 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,603 | $640 | Not Implemented |
WI0360 # 06 Y:1999 | 06 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,483 | $1,000 | Not Implemented |
WI0360 # 05 Y:1999 | 05 | 1999 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $2,661 | $8,000 | Not Implemented |
WI0360 # 04 Y:1999 | 04 | 1999 | REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF | $7,161 | $40,800 | Not Implemented |
WI0360 # 03 Y:1999 | 03 | 1999 | USE EVAPORATION TO CONCENTRATE MATERIAL | $15,954 | $16,000 | Not Implemented |
WI0360 # 02 Y:1999 | 02 | 1999 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $17,374 | $22,500 | Not Implemented |
WI0360 # 01 Y:1999 | 01 | 1999 | USE A DIFFERENT OR RECYCLED RAW MATERIAL | $24,990 | $0 | Not Implemented |
WI0360 # 11 Y:1999 | 11 | 1999 | REDUCE VENTILATION AIR | $1,891 | $500 | Implemented |
WI0360 # 12 Y:1999 | 12 | 1999 | INSTALL TIMERS AND/OR THERMOSTATS | $1,735 | $400 | Not Implemented |
WI0360 # 13 Y:1999 | 13 | 1999 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,148 | $725 | Not Implemented |
BD0132 # 10 Y:1999 | 10 | 1999 | INSTALL EQUIPMENT TO MOVE PRODUCT | $30,960 | $50,000 | Not Implemented |
BD0132 # 02 Y:1999 | 02 | 1999 | INSTALL OCCUPANCY SENSORS | $2,901 | $1,050 | Not Implemented |
BD0132 # 03 Y:1999 | 03 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,923 | $8,000 | Not Implemented |
BD0132 # 04 Y:1999 | 04 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,514 | $4,000 | Not Implemented |
BD0132 # 05 Y:1999 | 05 | 1999 | USE RADIANT HEATER FOR SPOT HEATING | $1,339 | $1,600 | Not Implemented |
BD0132 # 06 Y:1999 | 06 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $707 | $900 | Implemented |
BD0132 # 07 Y:1999 | 07 | 1999 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $2,232 | $4,200 | Implemented |
BD0132 # 08 Y:1999 | 08 | 1999 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,217 | $7,000 | Not Implemented |
BD0132 # 09 Y:1999 | 09 | 1999 | MINIMIZE WATER USAGE | $1,215 | $3,125 | Not Implemented |
BD0132 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,002 | $27,440 | Implemented |
BD0109 # 01 Y:1998 | 01 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,380 | $13,620 | Implemented |
BD0109 # 05 Y:1998 | 05 | 1998 | USE SYNTHETIC LUBRICANT | $396 | $200 | Implemented |
BD0109 # 06 Y:1998 | 06 | 1998 | RECOVER AND REUSE WASTE MATERIAL | $3,627 | $8,000 | Not Implemented |