Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,528
matching recommendationsSIC | 372 | Aircraft And Parts |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0240 # 04 Y:2024 | 04 | 2024 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,194 | $3,716 | Implemented |
DL0240 # 03 Y:2024 | 03 | 2024 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $40,323 | $0 | Implemented |
DL0240 # 02 Y:2024 | 02 | 2024 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $9,910 | $0 | Implemented |
DL0240 # 01 Y:2024 | 01 | 2024 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $12,775 | $0 | Implemented |
DL0240 # 08 Y:2024 | 08 | 2024 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $49,476 | $225,000 | Implemented |
OK1111 # 08 Y:2024 | 08 | 2024 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $499 | $236 | Not Implemented |
OK1111 # 07 Y:2024 | 07 | 2024 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $7,982 | $16,792 | Implemented |
OK1111 # 06 Y:2024 | 06 | 2024 | INSTALL OCCUPANCY SENSORS | $83 | $83 | Implemented |
OK1111 # 05 Y:2024 | 05 | 2024 | OPERATE BOILERS ON HIGH FIRE SETTING | $935 | $22,000 | Not Implemented |
OK1111 # 04 Y:2024 | 04 | 2024 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,608 | $3,599 | Implemented |
OK1111 # 03 Y:2024 | 03 | 2024 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $31,271 | $46,928 | Implemented |
OK1111 # 02 Y:2024 | 02 | 2024 | USE SOLAR HEAT TO MAKE ELECTRICTY | $129,812 | $935,220 | Not Implemented |
OK1111 # 01 Y:2024 | 01 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $46,469 | $113,104 | Implemented |
WM0221 # 06 Y:2024 | 06 | 2024 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $386 | $677 | Not Implemented |
WM0221 # 05 Y:2024 | 05 | 2024 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,454 | $2,360 | Implemented |
WM0221 # 04 Y:2024 | 04 | 2024 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,436 | $0 | Not Implemented |
WM0221 # 03 Y:2024 | 03 | 2024 | INSTALL OCCUPANCY SENSORS | $3,845 | $0 | Not Implemented |
WM0221 # 02 Y:2024 | 02 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,591 | $9,372 | Implemented |
WM0221 # 01 Y:2024 | 01 | 2024 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $13,280 | $0 | Implemented |
OK1109 # 09 Y:2024 | 09 | 2024 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $125 | $825 | Implemented |
OK1109 # 08 Y:2024 | 08 | 2024 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $18,482 | $120,578 | Implemented |
OK1109 # 07 Y:2024 | 07 | 2024 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $8,413 | $3,850 | Not Implemented |
OK1109 # 06 Y:2024 | 06 | 2024 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $5,867 | $38,775 | Implemented |
OK1109 # 05 Y:2024 | 05 | 2024 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $5,582 | $11,028 | Not Implemented |
OK1109 # 04 Y:2024 | 04 | 2024 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $213 | $820 | Not Implemented |