Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

272

matching recommendations
Reset
SIC 372 Aircraft And Parts
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0995 # 06 Y:2018 06 2018 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $444 $300 Implemented
OK0975 # 08 Y:2017 08 2017 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,181 $0 Not Implemented
OK0975 # 07 Y:2017 07 2017 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,048 $438 Not Implemented
OK0975 # 06 Y:2017 06 2017 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $9,429 $2,713 Not Implemented
OK0975 # 05 Y:2017 05 2017 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $685 $0 Not Implemented
OK0975 # 04 Y:2017 04 2017 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $2,312 $1,015 Not Implemented
OK0975 # 03 Y:2017 03 2017 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $9,584 $9,120 Not Implemented
OK0975 # 02 Y:2017 02 2017 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $19,832 $46,320 Not Implemented
OK0975 # 01 Y:2017 01 2017 OPTIMIZE PLANT POWER FACTOR $25,427 $24,531 Not Implemented
OK0915 # 13 Y:2015 13 2015 USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING $12,313 $21,480 Not Implemented
OK0915 # 01 Y:2015 01 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $58,176 $103,015 Implemented
OK0915 # 02 Y:2015 02 2015 INSTALL OCCUPANCY SENSORS $17,688 $25,096 Not Implemented
OK0915 # 03 Y:2015 03 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,867 $20,538 Implemented
OK0915 # 04 Y:2015 04 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,060 $24,180 Implemented
OK0915 # 05 Y:2015 05 2015 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $10,077 $6,900 Implemented
OK0915 # 06 Y:2015 06 2015 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $7,439 $14,107 Not Implemented
OK0915 # 07 Y:2015 07 2015 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $674 $382 Implemented
OK0915 # 08 Y:2015 08 2015 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $4,441 $14,342 Not Implemented
OK0915 # 09 Y:2015 09 2015 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $6,741 $3,938 Not Implemented
OK0915 # 10 Y:2015 10 2015 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $8,266 $63,126 Not Implemented
OK0915 # 12 Y:2015 12 2015 USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING $2,345 $5,403 Not Implemented
OK0915 # 11 Y:2015 11 2015 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $1,720 $3,060 Implemented
OK0915 # 14 Y:2015 14 2015 OPTIMIZE PLANT POWER FACTOR $9,371 $14,014 Not Implemented
OK0889 # 08 Y:2014 08 2014 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $815 $250 Not Implemented
OK0889 # 02 Y:2014 02 2014 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $4,415 $7,547 Not Implemented