IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,491

matching recommendations
Reset
SIC 372 Aircraft And Parts
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SU0268 # 08 Y:2008 08 2008 INSTALL OCCUPANCY SENSORS $318 $674 Implemented
SU0268 # 09 Y:2008 09 2008 OPTIMIZE PLANT POWER FACTOR $11,006 $39,533 Not Implemented
WV0372 # 01 Y:2008 01 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $28,998 $34,945 Not Implemented
WV0372 # 02 Y:2008 02 2008 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $13,813 $2,000 Implemented
WV0372 # 03 Y:2008 03 2008 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $10,188 $511 Implemented
WV0372 # 04 Y:2008 04 2008 RECOVER WASTE HEAT FROM EQUIPMENT $7,107 $540 Not Implemented
WV0372 # 05 Y:2008 05 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,593 $8,011 Implemented
WV0372 # 06 Y:2008 06 2008 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $5,074 $4,500 Implemented
WV0372 # 07 Y:2008 07 2008 DEVELOP A REPAIR/REPLACE POLICY $3,550 $890 Implemented
WV0372 # 08 Y:2008 08 2008 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,560 $2,750 Not Implemented
WV0372 # 09 Y:2008 09 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,523 $0 Implemented
WV0372 # 10 Y:2008 10 2008 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,153 $460 Not Implemented
SD0403 # 01 Y:2008 01 2008 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $148,069 $13,073 Implemented
SD0403 # 02 Y:2008 02 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $13,157 $15,033 Implemented
SD0403 # 03 Y:2008 03 2008 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $8,381 $13,275 Implemented
SD0403 # 04 Y:2008 04 2008 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,873 $6,500 Not Implemented
SD0403 # 05 Y:2008 05 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $58,026 $12,356 Not Implemented
SD0398 # 01 Y:2007 01 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $23,030 $45,224 Implemented
SD0398 # 02 Y:2007 02 2007 INSTALL SKYLIGHTS $4,253 $13,615 Not Implemented
SD0398 # 03 Y:2007 03 2007 REPAIR AND ELIMINATE STEAM LEAKS $2,091 $150 Implemented
SD0398 # 04 Y:2007 04 2007 PREHEAT COMBUSTION AIR WITH WASTE HEAT $1,860 $5,101 Not Implemented
SD0398 # 05 Y:2007 05 2007 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,353 $2,193 Not Implemented
CO0606 # 01 Y:2007 01 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,880 $620 Implemented
CO0606 # 02 Y:2007 02 2007 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $5,100 $60 Implemented
CO0606 # 03 Y:2007 03 2007 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $3,150 $2,680 Implemented