Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,491
matching recommendationsSIC | 372 | Aircraft And Parts |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0172 # 05 Y:1997 | 05 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,239 | $8,727 | Implemented |
SD0172 # 06 Y:1997 | 06 | 1997 | INSTALL SPECTRAL REFLECTORS / DELAMP | $8,038 | $12,145 | Implemented |
SD0172 # 07 Y:1997 | 07 | 1997 | INSTALL OCCUPANCY SENSORS | $2,285 | $902 | Implemented |
SD0172 # 08 Y:1997 | 08 | 1997 | USE SYNTHETIC LUBRICANT | $6,420 | $0 | Not Implemented |
SD0172 # 09 Y:1997 | 09 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $4,420 | $0 | Implemented |
SD0172 # 10 Y:1997 | 10 | 1997 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $3,341 | $2,000 | Implemented |
SD0172 # 11 Y:1997 | 11 | 1997 | MODIFY CURRENT INCENTIVE PROGRAM | $4,675 | $4,800 | Implemented |
SD0172 # 12 Y:1997 | 12 | 1997 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $41,221 | $200 | Implemented |
GT0602 # 01 Y:1996 | 01 | 1996 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $41,960 | $76,100 | Not Implemented |
GT0602 # 02 Y:1996 | 02 | 1996 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $1,330 | $500 | Not Implemented |
GT0602 # 03 Y:1996 | 03 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $690 | $300 | Implemented |
GT0602 # 04 Y:1996 | 04 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,980 | $1,000 | Implemented |
GT0602 # 05 Y:1996 | 05 | 1996 | INCREASE USE OF AUTOMATION | $20,487 | $8,000 | Not Implemented |
GT0602 # 06 Y:1996 | 06 | 1996 | USE PRECIPITATING AGENTS IN WASTE WATER TREATMENT THAT PRODUCE THE LEAST QUANTITY OF WASTE | $1,044 | $3,500 | Not Implemented |
AR0093 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $897 | $1,340 | Implemented |
AR0093 # 02 Y:1996 | 02 | 1996 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $7,652 | $3,285 | Implemented |
AR0093 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,945 | $2,535 | Implemented |
AR0093 # 04 Y:1996 | 04 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $390 | $110 | Implemented |
AR0093 # 05 Y:1996 | 05 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,289 | $6,000 | Not Implemented |
AR0093 # 06 Y:1996 | 06 | 1996 | MINIMIZE WATER USAGE | $912 | $10 | Implemented |
OK0498 # 01 Y:1996 | 01 | 1996 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,692 | $3,200 | Implemented |
OK0498 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,469 | $1,648 | Implemented |
OK0498 # 03 Y:1996 | 03 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,649 | $1,399 | Not Implemented |
OK0498 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,295 | $4,770 | Implemented |
OK0498 # 05 Y:1996 | 05 | 1996 | INSTALL OCCUPANCY SENSORS | $120 | $366 | Not Implemented |