Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Oklahoma State University |
---|---|
Assessment Year | 1998 |
Principal Product | Large Aircraft spare parts |
NAICS | n/a |
SIC | 3728 - Aircraft Parts And Equipment, Nec |
Sales | n/a |
# of Employees | 325 |
Plant Area (Sq.Ft.) | 130,000 |
Annual Production | 0 Units |
Production Hrs. Annual | 6,240 |
Location (State) | OK |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $331,193 | 7,598,476 | kWh | $0.04 |
Electricity Demand | $1,506 | - | kW-months/year | - |
Natural Gas | $54,748 | 10,388 | MMBtu | $5.27 |
TOTAL ENERGY COSTS | $3,188,056 | |||
RECOMMENDED SAVINGS* | $64,874 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $8,429 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,497 Cost: $26,747 |
$2,850 | 88,511 | $1,395 | 326 | - | - | - | - | $252 | - |
$2,850 88,511 kWh |
$1,395 326 kW-months/year |
- - MMBtu |
- - $ |
$252 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $48,699 Cost: $25,866 |
$5,666 | 175,850 | $1,448 | 338 | - | - | - | - | $41,585 | - |
$5,666 175,850 kWh |
$1,448 338 kW-months/year |
- - MMBtu |
- - $ |
$41,585 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $819 Cost: $700 |
$216 | 6,741 | $39 | 9 | - | - | $326 | - | $238 | - |
$216 6,741 kWh |
$39 9 kW-months/year |
- - MMBtu |
$326 - $ |
$238 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $873 Cost: $651 |
$873 | 26,964 | - | - | - | - | - | - | - | - |
$873 26,964 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $142 Cost: $54 |
$127 | 4,103 | $15 | 4 | - | - | - | - | - | - |
$127 4,103 kWh |
$15 4 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $581 Cost: $375 |
$581 | 18,171 | - | - | - | - | - | - | - | - |
$581 18,171 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.1241 REDUCE EXCESSIVE BOILER BLOWDOWN |
Savings: $1,324 Cost: $5,000 |
- | - | - | - | $1,324 | 261 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,324 261 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $193 Cost: $209 |
$193 | 11,137 | - | - | - | - | - | - | - | - |
$193 11,137 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT |
Savings: $1,072 Cost: $7,000 |
$1,072 | 33,411 | - | - | - | - | - | - | - | - |
$1,072 33,411 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $1,474 Cost: $6,000 |
- | - | $1,474 | 515 | - | - | - | - | - | - |
- - kWh |
$1,474 515 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.4131 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY |
Savings: $3,909 Cost: $15,000 |
$3,909 | 121,336 | - | - | - | - | - | - | - | - |
$3,909 121,336 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $1,291 Cost: $3,000 |
- | - | - | - | - | - | - | - | $1,291 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$1,291 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $64,874 Cost: $90,602 |
$15,487 | 486,224 | $4,371 | 1,192 | $1,324 | 261 | $326 | - | $43,366 | - | $15,487 486,224 kWh |
$4,371 1,192 kW-months/year |
$1,324 261 MMBtu |
$326 - $ |
$43,366 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $8,429 Cost: $33,736 |
$4,840 | 155,627 | $1,449 | 339 | $1,324 | 261 | $326 | - | $490 | - | $4,840 155,627 kWh |
$1,449 339 kW-months/year |
$1,324 261 MMBtu |
$326 - $ |
$490 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost |