Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
64
matching recommendationsSIC | 3721 | Aircraft |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0376 # 08 Y:2020 | 08 | 2020 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $763 | $289 | Not Implemented |
MI0376 # 07 Y:2020 | 07 | 2020 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $3,944 | $440 | Not Implemented |
MI0376 # 06 Y:2020 | 06 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,838 | $9,120 | Implemented |
MI0376 # 05 Y:2020 | 05 | 2020 | INSTALL SPECTRAL REFLECTORS / DELAMP | $6,695 | $5,875 | Not Implemented |
MI0376 # 04 Y:2020 | 04 | 2020 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $25,854 | $580 | Not Implemented |
MI0376 # 01 Y:2020 | 01 | 2020 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $234,414 | $800 | Not Implemented |
MI0376 # 02 Y:2020 | 02 | 2020 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $205,000 | $1,013,224 | Not Implemented |
MI0376 # 03 Y:2020 | 03 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $55,477 | $1,980 | Not Implemented |
MI0196 # 02 Y:2010 | 02 | 2010 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $113,486 | $143,892 | Not Implemented |
MI0196 # 05 Y:2010 | 05 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $12,467 | $40 | Not Implemented |
MI0196 # 04 Y:2010 | 04 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $34,243 | $1,210 | Implemented |
MI0196 # 03 Y:2010 | 03 | 2010 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $108,082 | $2,000 | Implemented |
MI0196 # 01 Y:2010 | 01 | 2010 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $157,910 | $102,500 | Implemented |
MI0196 # 06 Y:2010 | 06 | 2010 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $3,786 | $4,531 | Not Implemented |
UF0435 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $38,247 | $18,650 | Implemented |
UF0435 # 05 Y:2010 | 05 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $7,752 | $772 | Not Implemented |
UF0435 # 04 Y:2010 | 04 | 2010 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $634 | $20 | Implemented |
UF0435 # 01 Y:2010 | 01 | 2010 | INSTALL OCCUPANCY SENSORS | $60,031 | $5,388 | Not Implemented |
UF0435 # 03 Y:2010 | 03 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,927 | $9,651 | Implemented |
UF0402 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $64,361 | $80,399 | Not Implemented |
UF0402 # 06 Y:2007 | 06 | 2007 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $13,315 | $57,868 | Not Implemented |
UF0402 # 07 Y:2007 | 07 | 2007 | INSTALL OCCUPANCY SENSORS | $3,641 | $194 | Implemented |
UF0402 # 04 Y:2007 | 04 | 2007 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $2,214 | $0 | Implemented |
UF0402 # 09 Y:2007 | 09 | 2007 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $38,931 | $2,136 | Not Implemented |
UF0402 # 11 Y:2007 | 11 | 2007 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $4,118 | $1,373 | Not Implemented |