Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,680
matching recommendationsSIC | 3728 | Aircraft Parts And Equipment, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LM0022 # 02 Y:2001 | 02 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,848 | $164 | Not Implemented |
LM0022 # 03 Y:2001 | 03 | 2001 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $54,047 | $450 | Implemented |
LM0022 # 04 Y:2001 | 04 | 2001 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $28,008 | $15,300 | Not Implemented |
LM0022 # 05 Y:2001 | 05 | 2001 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $57,000 | $102,000 | Implemented |
MI0011 # 01 Y:2001 | 01 | 2001 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $59,040 | $5,100 | Implemented |
MI0011 # 02 Y:2001 | 02 | 2001 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $73,364 | $5,100 | Implemented |
MI0011 # 03 Y:2001 | 03 | 2001 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $18,892 | $5,100 | Implemented |
MI0011 # 04 Y:2001 | 04 | 2001 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $114,007 | $5,100 | Implemented |
MI0011 # 05 Y:2001 | 05 | 2001 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $316,160 | $164,000 | Implemented |
MI0011 # 06 Y:2001 | 06 | 2001 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $27,793 | $19 | Implemented |
MI0011 # 07 Y:2001 | 07 | 2001 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $10,662 | $760 | Not Implemented |
MI0001 # 01 Y:2001 | 01 | 2001 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,545 | $200 | Not Implemented |
MI0001 # 02 Y:2001 | 02 | 2001 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $24,240 | $20,000 | n/a |
MI0001 # 03 Y:2001 | 03 | 2001 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $96,000 | $25,000 | Implemented |
MI0001 # 04 Y:2001 | 04 | 2001 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,041 | $1,360 | Not Implemented |
MI0001 # 05 Y:2001 | 05 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $480 | $60 | Implemented |
OK0598 # 01 Y:2000 | 01 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $789 | $2,250 | Implemented |
OK0598 # 02 Y:2000 | 02 | 2000 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,182 | $700 | Implemented |
OK0598 # 03 Y:2000 | 03 | 2000 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $323 | $86 | Not Implemented |
OK0598 # 04 Y:2000 | 04 | 2000 | INSTALL OCCUPANCY SENSORS | $887 | $1,980 | Not Implemented |
OK0598 # 05 Y:2000 | 05 | 2000 | INSTALL SET-BACK TIMERS | $535 | $936 | Implemented |
OK0598 # 06 Y:2000 | 06 | 2000 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $920 | $2,000 | Not Implemented |
OK0598 # 07 Y:2000 | 07 | 2000 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $27,300 | $16,150 | Not Implemented |
GT0659 # 01 Y:1999 | 01 | 1999 | USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS | $88,180 | $220,000 | n/a |
GT0659 # 02 Y:1999 | 02 | 1999 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $3,484 | $0 | n/a |