Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
397
matching recommendationsSIC | 373 | Ship And Boat Building And Repairing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0162 # 02 Y:1992 | 02 | 1992 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $1,150 | $5,746 | Implemented |
AM0162 # 03 Y:1992 | 03 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,010 | $300 | Implemented |
AM0162 # 04 Y:1992 | 04 | 1992 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $700 | $215 | Implemented |
UF0041 # 01 Y:1992 | 01 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,221 | $798 | Implemented |
UF0041 # 05 Y:1992 | 05 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $775 | $7,950 | Implemented |
UF0041 # 06 Y:1992 | 06 | 1992 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $125 | $660 | Implemented |
UF0041 # 04 Y:1992 | 04 | 1992 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $400 | $1,200 | Implemented |
UF0008 # 01 Y:1991 | 01 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,718 | $0 | Implemented |
UF0008 # 06 Y:1991 | 06 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $562 | $966 | Implemented |
UF0008 # 05 Y:1991 | 05 | 1991 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,420 | $0 | Implemented |
UF0008 # 04 Y:1991 | 04 | 1991 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $5,075 | $3,100 | Implemented |
UF0008 # 03 Y:1991 | 03 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $137 | $569 | Implemented |
UF0008 # 02 Y:1991 | 02 | 1991 | KEEP LAMPS AND REFLECTORS CLEAN | $27,276 | $0 | Implemented |
OK0342 # 06 Y:1991 | 06 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $896 | $2,600 | Implemented |
OK0342 # 05 Y:1991 | 05 | 1991 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,644 | $3,510 | Implemented |
OK0342 # 04 Y:1991 | 04 | 1991 | INSTALL TIMERS AND/OR THERMOSTATS | $10,794 | $6,200 | Implemented |
OK0342 # 03 Y:1991 | 03 | 1991 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,397 | $0 | Implemented |
OK0342 # 02 Y:1991 | 02 | 1991 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $445 | $0 | Implemented |
OK0342 # 01 Y:1991 | 01 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,190 | $276 | Implemented |
WI0060 # 01 Y:1989 | 01 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $6,260 | $1,800 | Implemented |
WI0060 # 03 Y:1989 | 03 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,289 | $1,193 | Implemented |
WI0060 # 04 Y:1989 | 04 | 1989 | INSTALL AUTOMATIC STACK DAMPER | $2,209 | $1,200 | Implemented |
LT0114 # 09 Y:1988 | 09 | 1988 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,400 | $450 | Implemented |
TN0318 # 02 Y:1987 | 02 | 1987 | RECOVER WASTE HEAT FROM EQUIPMENT | $489 | $700 | Implemented |
TN0318 # 03 Y:1987 | 03 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,614 | $195 | Implemented |