IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

798

matching recommendations
Reset
SIC 373 Ship And Boat Building And Repairing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0636 # 08 Y:1998 08 1998 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $825,000 $0 Not Implemented
NV0126 # 01 Y:1999 01 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $284 $70 Implemented
NV0126 # 02 Y:1999 02 1999 UPGRADE CONTROLS ON COMPRESSORS $1,034 $500 Not Implemented
NV0126 # 03 Y:1999 03 1999 USE RADIANT HEATER FOR SPOT HEATING $6,540 $7,980 Not Implemented
NV0126 # 04 Y:1999 04 1999 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $821 $1,300 Implemented
NV0126 # 05 Y:1999 05 1999 INSTALL TIMERS AND/OR THERMOSTATS $4,515 $1,400 Implemented
UF0198 # 01 Y:1998 01 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,183 $32,433 Not Implemented
UF0198 # 02 Y:1998 02 1998 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $1,359 $260 Implemented
UF0198 # 03 Y:1998 03 1998 USE RADIANT HEATER FOR SPOT HEATING $4,544 $14,018 Not Implemented
UF0198 # 04 Y:1998 04 1998 CHECK FOR ACCURACY OF UTILITY / POWER METERS $5,355 $787 Implemented
UF0198 # 05 Y:1998 05 1998 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $6,288 $0 Not Implemented
UF0198 # 06 Y:1998 06 1998 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES $19,226 $2,000 Not Implemented
UF0198 # 07 Y:1998 07 1998 ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL $3,250 $15,000 Not Implemented
UF0198 # 08 Y:1998 08 1998 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $4,848 $750 Not Implemented
OR0314 # 01 Y:1998 01 1998 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $9,110 $0 Implemented
OR0314 # 02 Y:1998 02 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,164 $4,524 Implemented
OR0314 # 03 Y:1998 03 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,150 $5,034 Implemented
OR0314 # 04 Y:1998 04 1998 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,645 $500 Implemented
OR0314 # 05 Y:1998 05 1998 BURN A LESS EXPENSIVE GRADE OF FUEL $1,200 $10,000 Not Implemented
OR0314 # 06 Y:1998 06 1998 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,787 $2,000 Implemented
OR0314 # 07 Y:1998 07 1998 INSTALL EFFICIENT RECTIFIERS $1,220 $7,900 Not Implemented
OR0314 # 08 Y:1998 08 1998 UPGRADE CONTROLS ON COMPRESSORS $4,685 $3,280 Implemented
OR0314 # 09 Y:1998 09 1998 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $9,562 $6,000 Not Implemented
OD0101 # 01 Y:1998 01 1998 BURN WASTE OIL FOR HEAT $5,664 $28,850 Not Implemented
OD0101 # 02 Y:1998 02 1998 USE A DIFFERENT OR RECYCLED RAW MATERIAL $106,000 $252,000 Implemented