Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
126
matching recommendationsSIC | 3731 | Ship Building And Repairing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0209 # 01 Y:2004 | 01 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $107,401 | $19,500 | Implemented |
LL0209 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,303 | $12,640 | Implemented |
LL0209 # 03 Y:2004 | 03 | 2004 | USE PHOTOCELL CONTROLS | $8,552 | $882 | Implemented |
LL0209 # 04 Y:2004 | 04 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,124 | $30 | Implemented |
LL0209 # 05 Y:2004 | 05 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,679 | $489 | Implemented |
LL0209 # 06 Y:2004 | 06 | 2004 | INSTALL OCCUPANCY SENSORS | $1,024 | $1,080 | Implemented |
LL0203 # 01 Y:2004 | 01 | 2004 | USE PHOTOCELL CONTROLS | $7,245 | $420 | Implemented |
LL0203 # 02 Y:2004 | 02 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,949 | $5,615 | Implemented |
LL0203 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,314 | $2,000 | Implemented |
LL0203 # 07 Y:2004 | 07 | 2004 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $4,000 | $60 | Implemented |
LL0203 # 08 Y:2004 | 08 | 2004 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $3,870 | $1,014 | Implemented |
LL0202 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $69,470 | $20,680 | Implemented |
LL0202 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,972 | $500 | Implemented |
LL0202 # 04 Y:2004 | 04 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,675 | $30 | Implemented |
LL0201 # 01 Y:2004 | 01 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $8,219 | $5,615 | Implemented |
LL0201 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,772 | $3,240 | Implemented |
LL0201 # 03 Y:2004 | 03 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,084 | $30 | Implemented |
LL0201 # 04 Y:2004 | 04 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,265 | $195 | Implemented |
LL0201 # 05 Y:2004 | 05 | 2004 | USE PHOTOCELL CONTROLS | $1,522 | $300 | Implemented |
LL0201 # 06 Y:2004 | 06 | 2004 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $227 | $198 | Implemented |
LL0201 # 07 Y:2004 | 07 | 2004 | INSTALL OCCUPANCY SENSORS | $151 | $90 | Implemented |
LL0201 # 08 Y:2004 | 08 | 2004 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $2,500 | $60 | Implemented |
LL0200 # 01 Y:2004 | 01 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $23,139 | $810 | Implemented |
LL0200 # 04 Y:2004 | 04 | 2004 | USE PHOTOCELL CONTROLS | $8,001 | $420 | Implemented |
LL0200 # 05 Y:2004 | 05 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,518 | $30 | Implemented |