Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
88
matching recommendationsSIC | 3732 | Boat Building And Repairing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0266 # 08 Y:2014 | 08 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,899 | $80 | Implemented |
MI0266 # 09 Y:2014 | 09 | 2014 | USE PHOTOCELL CONTROLS | $1,450 | $360 | Implemented |
MI0266 # 03 Y:2014 | 03 | 2014 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $7,871 | $640 | Implemented |
MI0266 # 02 Y:2014 | 02 | 2014 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $8,400 | $800 | Implemented |
MI0266 # 06 Y:2014 | 06 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,486 | $1,310 | Implemented |
MI0266 # 07 Y:2014 | 07 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,344 | $9,120 | Implemented |
MI0266 # 05 Y:2014 | 05 | 2014 | INSTALL SKYLIGHTS | $5,746 | $630 | Implemented |
MI0264 # 04 Y:2014 | 04 | 2014 | INSTALL SKYLIGHTS | $12,707 | $1,600 | Implemented |
MI0264 # 18 Y:2014 | 18 | 2014 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,127 | $80 | Implemented |
MI0264 # 17 Y:2014 | 17 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,179 | $80 | Implemented |
MI0264 # 16 Y:2014 | 16 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,316 | $80 | Implemented |
MI0264 # 15 Y:2014 | 15 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,646 | $1,660 | Implemented |
MI0264 # 14 Y:2014 | 14 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,886 | $1,660 | Implemented |
MI0264 # 12 Y:2014 | 12 | 2014 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $2,115 | $520 | Implemented |
MI0264 # 10 Y:2014 | 10 | 2014 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,344 | $4,800 | Implemented |
MI0264 # 08 Y:2014 | 08 | 2014 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $5,408 | $140 | Implemented |
MI0264 # 07 Y:2014 | 07 | 2014 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $7,073 | $1,000 | Implemented |
MI0264 # 06 Y:2014 | 06 | 2014 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $8,019 | $80 | Implemented |
MI0264 # 03 Y:2014 | 03 | 2014 | USE PHOTOCELL CONTROLS | $15,757 | $840 | Implemented |
MI0260 # 15 Y:2014 | 15 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $521 | $80 | Implemented |
MI0260 # 12 Y:2014 | 12 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $649 | $80 | Implemented |
MI0260 # 06 Y:2014 | 06 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,062 | $80 | Implemented |
MI0260 # 07 Y:2014 | 07 | 2014 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,236 | $5,000 | Implemented |
MI0260 # 08 Y:2014 | 08 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,278 | $1,660 | Implemented |
MI0260 # 09 Y:2014 | 09 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,716 | $1,660 | Implemented |