IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

281

matching recommendations
Reset
SIC 374 Railroad Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0550 # 11 Y:2004 11 2004 PAY BILLS ON TIME TO AVOID LATE FEES $390 $0 Implemented
SU0134 # 01 Y:2002 01 2002 INSTALL / REPAIR INSULATION ON STEAM LINES $14,024 $6,613 Not Implemented
SU0134 # 02 Y:2002 02 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $11,420 $89 Implemented
SU0134 # 03 Y:2002 03 2002 OPTIMIZE PLANT POWER FACTOR $8,470 $23,250 Not Implemented
SU0134 # 04 Y:2002 04 2002 REPAIR AND ELIMINATE STEAM LEAKS $4,103 $178 Not Implemented
SU0134 # 05 Y:2002 05 2002 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $4,031 $706 Not Implemented
SU0134 # 06 Y:2002 06 2002 COVER OPEN TANKS $2,938 $1,769 Not Implemented
SU0134 # 07 Y:2002 07 2002 INSTALL OCCUPANCY SENSORS $1,453 $299 Implemented
SU0134 # 08 Y:2002 08 2002 REPAIR AND ELIMINATE STEAM LEAKS $1,197 $22 Not Implemented
SU0134 # 09 Y:2002 09 2002 INSULATE BARE EQUIPMENT $686 $1,106 Not Implemented
SU0134 # 10 Y:2002 10 2002 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $288 $0 Implemented
TP0008 # 01 Y:1999 01 1999 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $24,189 $1,848 Implemented
TP0008 # 02 Y:1999 02 1999 OPTIMIZE PLANT POWER FACTOR $33,041 $51,500 Not Implemented
TP0008 # 03 Y:1999 03 1999 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $36,820 $1,728 Not Implemented
TP0008 # 04 Y:1999 04 1999 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $7,545 $2,000 Not Implemented
TP0008 # 05 Y:1999 05 1999 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,456 $35,097 Not Implemented
TP0008 # 06 Y:1999 06 1999 USE SYNTHETIC LUBRICANT $1,248 $0 Not Implemented
WV0179 # 01 Y:1999 01 1999 USE SYNTHETIC LUBRICANT $163 $312 Implemented
WV0179 # 02 Y:1999 02 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $200 $174 Implemented
WV0179 # 03 Y:1999 03 1999 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $455 $270 Implemented
WV0179 # 04 Y:1999 04 1999 INSTALL SPECTRAL REFLECTORS / DELAMP $2,465 $7,820 Not Implemented
WV0179 # 05 Y:1999 05 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $218 $36 Implemented
WV0179 # 06 Y:1999 06 1999 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $1,773 $7,500 Implemented
WV0179 # 07 Y:1999 07 1999 USE MINIMUM SAFE OVEN VENTILATION $574 $54 Implemented
WV0179 # 08 Y:1999 08 1999 USE OPTIMUM THICKNESS INSULATION $1,109 $675 Implemented