Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

43

matching recommendations
Reset
SIC 3795 Tanks And Tank Components
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UA0180 # 08 Y:2017 08 2017 TURN OFF EQUIPMENT WHEN NOT IN USE $240 $50 Implemented
UA0180 # 07 Y:2017 07 2017 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $327 $735 Implemented
UA0180 # 06 Y:2017 06 2017 PAY BILLS ON TIME TO AVOID LATE FEES $296 $0 Implemented
UA0180 # 05 Y:2017 05 2017 MODIFY STARTUP/SHUTDOWN TIMES $2,873 $0 Not Implemented
UA0180 # 01 Y:2017 01 2017 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,799 $2,645 Implemented
UA0180 # 02 Y:2017 02 2017 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $5,724 $3,250 Not Implemented
UA0180 # 03 Y:2017 03 2017 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $5,029 $400 Not Implemented
UA0180 # 04 Y:2017 04 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,573 $25,654 Not Implemented
UD0929 # 04 Y:2015 04 2015 REDUCE EXCESSIVE BOILER BLOWDOWN $61,951 $15,000 Not Implemented
UD0929 # 01 Y:2015 01 2015 BURN A LESS EXPENSIVE GRADE OF FUEL $424,424 $0 Implemented
UD0929 # 02 Y:2015 02 2015 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $90,554 $10,250 Not Implemented
UD0929 # 03 Y:2015 03 2015 INSTALL SET-BACK TIMERS $225,530 $1,200 Not Implemented
UD0929 # 06 Y:2015 06 2015 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $658,499 $100,000 Implemented
UD0929 # 07 Y:2015 07 2015 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $290,782 $0 Not Implemented
UD0929 # 05 Y:2015 05 2015 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,522 $12,800 Implemented
UD0890 # 04 Y:2013 04 2013 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $136,711 $0 Implemented
UD0890 # 12 Y:2013 12 2013 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $19,159 $0 Not Implemented
UD0890 # 11 Y:2013 11 2013 USE RADIANT HEATER FOR SPOT HEATING $565,879 $1,157,500 Not Implemented
UD0890 # 10 Y:2013 10 2013 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $746,973 $100,000 Not Implemented
UD0890 # 09 Y:2013 09 2013 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $176,886 $101,000 Not Implemented
UD0890 # 08 Y:2013 08 2013 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $6,203 $0 Implemented
UD0890 # 07 Y:2013 07 2013 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $37,438 $6,000 Implemented
UD0890 # 06 Y:2013 06 2013 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $5,216 $0 Implemented
UD0890 # 05 Y:2013 05 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,587 $19,427 Not Implemented
UD0890 # 03 Y:2013 03 2013 CHECK FOR ACCURACY OF UTILITY / POWER METERS $37,340 $0 Implemented