Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
43
matching recommendationsSIC | 3795 | Tanks And Tank Components |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0180 # 08 Y:2017 | 08 | 2017 | TURN OFF EQUIPMENT WHEN NOT IN USE | $240 | $50 | Implemented |
UA0180 # 07 Y:2017 | 07 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $327 | $735 | Implemented |
UA0180 # 06 Y:2017 | 06 | 2017 | PAY BILLS ON TIME TO AVOID LATE FEES | $296 | $0 | Implemented |
UA0180 # 05 Y:2017 | 05 | 2017 | MODIFY STARTUP/SHUTDOWN TIMES | $2,873 | $0 | Not Implemented |
UA0180 # 01 Y:2017 | 01 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,799 | $2,645 | Implemented |
UA0180 # 02 Y:2017 | 02 | 2017 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $5,724 | $3,250 | Not Implemented |
UA0180 # 03 Y:2017 | 03 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,029 | $400 | Not Implemented |
UA0180 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,573 | $25,654 | Not Implemented |
UD0929 # 04 Y:2015 | 04 | 2015 | REDUCE EXCESSIVE BOILER BLOWDOWN | $61,951 | $15,000 | Not Implemented |
UD0929 # 01 Y:2015 | 01 | 2015 | BURN A LESS EXPENSIVE GRADE OF FUEL | $424,424 | $0 | Implemented |
UD0929 # 02 Y:2015 | 02 | 2015 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $90,554 | $10,250 | Not Implemented |
UD0929 # 03 Y:2015 | 03 | 2015 | INSTALL SET-BACK TIMERS | $225,530 | $1,200 | Not Implemented |
UD0929 # 06 Y:2015 | 06 | 2015 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $658,499 | $100,000 | Implemented |
UD0929 # 07 Y:2015 | 07 | 2015 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $290,782 | $0 | Not Implemented |
UD0929 # 05 Y:2015 | 05 | 2015 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,522 | $12,800 | Implemented |
UD0890 # 04 Y:2013 | 04 | 2013 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $136,711 | $0 | Implemented |
UD0890 # 12 Y:2013 | 12 | 2013 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $19,159 | $0 | Not Implemented |
UD0890 # 11 Y:2013 | 11 | 2013 | USE RADIANT HEATER FOR SPOT HEATING | $565,879 | $1,157,500 | Not Implemented |
UD0890 # 10 Y:2013 | 10 | 2013 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $746,973 | $100,000 | Not Implemented |
UD0890 # 09 Y:2013 | 09 | 2013 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $176,886 | $101,000 | Not Implemented |
UD0890 # 08 Y:2013 | 08 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,203 | $0 | Implemented |
UD0890 # 07 Y:2013 | 07 | 2013 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $37,438 | $6,000 | Implemented |
UD0890 # 06 Y:2013 | 06 | 2013 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $5,216 | $0 | Implemented |
UD0890 # 05 Y:2013 | 05 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,587 | $19,427 | Not Implemented |
UD0890 # 03 Y:2013 | 03 | 2013 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $37,340 | $0 | Implemented |