Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,140
matching recommendationsSIC | 38 | Instruments And Related Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0203 # 01 Y:1986 | 01 | 1986 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $11,062 | $4,000 | Not Implemented |
KU0203 # 02 Y:1986 | 02 | 1986 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $190 | $10 | Implemented |
KU0203 # 03 Y:1986 | 03 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,598 | $10,800 | Implemented |
KU0203 # 04 Y:1986 | 04 | 1986 | INSTALL TIMERS AND/OR THERMOSTATS | $5,188 | $1,000 | Implemented |
KU0203 # 05 Y:1986 | 05 | 1986 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $1,800 | $300 | Implemented |
KU0203 # 06 Y:1986 | 06 | 1986 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,080 | $1,500 | Not Implemented |
KU0203 # 07 Y:1986 | 07 | 1986 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $730 | $117 | Implemented |
KU0203 # 08 Y:1986 | 08 | 1986 | INSTALL AUTOMATIC STACK DAMPER | $303 | $750 | Implemented |
KU0203 # 09 Y:1986 | 09 | 1986 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $285 | $0 | Implemented |
KU0203 # 10 Y:1986 | 10 | 1986 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $115 | $250 | Implemented |
OK0206 # 01 Y:1986 | 01 | 1986 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $1,270 | $3,500 | Implemented |
OK0206 # 02 Y:1986 | 02 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,340 | $1,056 | Implemented |
OK0206 # 03 Y:1986 | 03 | 1986 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $743 | $4,000 | Implemented |
GT0290 # 01 Y:1986 | 01 | 1986 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $8,798 | $12,000 | Implemented |
GT0290 # 02 Y:1986 | 02 | 1986 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $636 | $0 | Implemented |
GT0290 # 03 Y:1986 | 03 | 1986 | IMPROVE LUBRICATION PRACTICES | $185 | $64 | Implemented |
OK0198 # 01 Y:1986 | 01 | 1986 | COVER OPEN TANKS | $1,722 | $426 | Not Implemented |
OK0198 # 02 Y:1986 | 02 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $340 | $60 | Not Implemented |
OK0198 # 03 Y:1986 | 03 | 1986 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $101 | $49 | Not Implemented |
OK0198 # 04 Y:1986 | 04 | 1986 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $5,532 | $22,000 | Not Implemented |
OK0198 # 05 Y:1986 | 05 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,027 | $276 | Implemented |
OK0198 # 07 Y:1986 | 07 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,856 | $3,272 | Implemented |
UD0191 # 01 Y:1986 | 01 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,942 | $7,500 | Implemented |
TN0271 # 01 Y:1986 | 01 | 1986 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $1,555 | $0 | Not Implemented |
TN0271 # 02 Y:1986 | 02 | 1986 | INSTALL / REPAIR INSULATION ON STEAM LINES | $944 | $287 | Implemented |