Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
149
matching recommendationsSIC | 38 | Instruments And Related Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0218 # 04 Y:2016 | 04 | 2016 | INSTALL OCCUPANCY SENSORS | $2,293 | $900 | Implemented |
MZ0218 # 06 Y:2016 | 06 | 2016 | INSTALL OCCUPANCY SENSORS | $1,603 | $900 | Implemented |
MZ0217 # 06 Y:2016 | 06 | 2016 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $7,627 | $20,000 | Not Implemented |
MZ0218 # 05 Y:2016 | 05 | 2016 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $3,810 | $0 | Not Implemented |
MZ0217 # 04 Y:2016 | 04 | 2016 | INSTALL OCCUPANCY SENSORS | $6,607 | $3,000 | Implemented |
MZ0217 # 01 Y:2016 | 01 | 2016 | CONDENSE OPERATION INTO ONE BUILDING | $4,197 | $900 | Implemented |
MZ0217 # 02 Y:2016 | 02 | 2016 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $27,674 | $30,000 | Not Implemented |
MZ0212 # 04 Y:2016 | 04 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,550 | $920 | Implemented |
MZ0212 # 03 Y:2016 | 03 | 2016 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $859 | $1,000 | Not Implemented |
MZ0212 # 09 Y:2016 | 09 | 2016 | USE PHOTOCELL CONTROLS | $1,863 | $750 | Not Implemented |
MZ0212 # 10 Y:2016 | 10 | 2016 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $825 | $3,500 | Implemented |
MZ0212 # 08 Y:2016 | 08 | 2016 | INSTALL OCCUPANCY SENSORS | $1,139 | $300 | Not Implemented |
MZ0212 # 01 Y:2016 | 01 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $162 | $0 | Not Implemented |
MZ0212 # 02 Y:2016 | 02 | 2016 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $6,016 | $7,700 | Not Implemented |
MZ0212 # 06 Y:2016 | 06 | 2016 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $632 | $0 | Implemented |
MZ0212 # 07 Y:2016 | 07 | 2016 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,393 | $0 | Implemented |
MZ0212 # 05 Y:2016 | 05 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,509 | $34,515 | Implemented |
KU0554 # 05 Y:2000 | 05 | 2000 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $620 | $2,000 | Not Implemented |
KU0554 # 04 Y:2000 | 04 | 2000 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,445 | $0 | Implemented |
KU0554 # 03 Y:2000 | 03 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,480 | $1,810 | Not Implemented |
KU0554 # 02 Y:2000 | 02 | 2000 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,829 | $0 | Implemented |
KU0554 # 01 Y:2000 | 01 | 2000 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $2,875 | $13,000 | Not Implemented |
KU0548 # 02 Y:2000 | 02 | 2000 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $6,154 | $11,500 | n/a |
KU0548 # 06 Y:2000 | 06 | 2000 | MINIMIZE WATER USAGE | $4,075 | $4,075 | n/a |
KU0548 # 05 Y:2000 | 05 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,422 | $1,050 | n/a |