Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
117
matching recommendationsSIC | 38 | Instruments And Related Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0516 # 01 Y:1997 | 01 | 1997 | INSTALL SET-BACK TIMERS | $2,215 | $3,472 | Implemented |
OK0516 # 02 Y:1997 | 02 | 1997 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $5,088 | $0 | Not Implemented |
OK0516 # 03 Y:1997 | 03 | 1997 | INSTALL OCCUPANCY SENSORS | $415 | $1,056 | Not Implemented |
OK0516 # 04 Y:1997 | 04 | 1997 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $304 | $542 | Implemented |
OK0516 # 05 Y:1997 | 05 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $269 | $395 | Implemented |
OK0458 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $616 | $3,962 | Not Implemented |
OK0458 # 02 Y:1995 | 02 | 1995 | INSTALL OCCUPANCY SENSORS | $662 | $760 | Not Implemented |
OK0458 # 03 Y:1995 | 03 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $633 | $727 | Not Implemented |
OK0458 # 04 Y:1995 | 04 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,010 | $170 | Not Implemented |
OK0458 # 05 Y:1995 | 05 | 1995 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $60 | $108 | Not Implemented |
OK0458 # 06 Y:1995 | 06 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,081 | $10,307 | Not Implemented |
OK0396 # 01 Y:1993 | 01 | 1993 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $3,199 | $8,100 | Implemented |
OK0396 # 02 Y:1993 | 02 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,139 | $80 | Implemented |
OK0396 # 03 Y:1993 | 03 | 1993 | INSTALL SET-BACK TIMERS | $1,153 | $570 | Not Implemented |
OK0396 # 04 Y:1993 | 04 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $904 | $270 | Implemented |
OK0396 # 05 Y:1993 | 05 | 1993 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $286 | $0 | Implemented |
OK0396 # 06 Y:1993 | 06 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $511 | $0 | Not Implemented |
OK0396 # 07 Y:1993 | 07 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $240 | $897 | Implemented |
OK0391 # 01 Y:1992 | 01 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,850 | $73,884 | Not Implemented |
OK0391 # 02 Y:1992 | 02 | 1992 | KEEP LAMPS AND REFLECTORS CLEAN | $2,101 | $4,704 | Not Implemented |
OK0391 # 03 Y:1992 | 03 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $302 | $0 | Implemented |
OK0391 # 04 Y:1992 | 04 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $472 | $444 | Not Implemented |
OK0391 # 05 Y:1992 | 05 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $966 | $1,880 | Implemented |
OK0391 # 06 Y:1992 | 06 | 1992 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $3,908 | $4,518 | Not Implemented |
OK0213 # 01 Y:1987 | 01 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $100 | $62 | Implemented |