Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
244
matching recommendationsSIC | 38 | Instruments And Related Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0388 # 08 Y:1997 | 08 | 1997 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $1,180 | $1,500 | Not Implemented |
CO0388 # 09 Y:1997 | 09 | 1997 | ELIMINATE/REDUCE REDUNDANT INSPECTIONS | $5,910 | $14,000 | Implemented |
CO0384 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,711 | $2,985 | Implemented |
CO0384 # 02 Y:1997 | 02 | 1997 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,050 | $4,840 | Not Implemented |
CO0384 # 03 Y:1997 | 03 | 1997 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $920 | $300 | Not Implemented |
CO0384 # 04 Y:1997 | 04 | 1997 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $530 | $500 | Not Implemented |
CO0384 # 05 Y:1997 | 05 | 1997 | COVER CONTAINERS TO MINIMIZE EVAPORATIVE LOSSES | $1,680 | $10,000 | Not Implemented |
CO0384 # 06 Y:1997 | 06 | 1997 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $620 | $760 | Not Implemented |
CO0384 # 07 Y:1997 | 07 | 1997 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $26,000 | $4,000 | Implemented |
CO0384 # 08 Y:1997 | 08 | 1997 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $10,500 | $30,000 | Not Implemented |
CO0343 # 01 Y:1995 | 01 | 1995 | ADD AREA LIGHTING SWITCHES | $2,470 | $300 | Not Implemented |
CO0343 # 02 Y:1995 | 02 | 1995 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,910 | $4,320 | Not Implemented |
CO0343 # 03 Y:1995 | 03 | 1995 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,400 | $5,210 | Not Implemented |
CO0343 # 04 Y:1995 | 04 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,180 | $2,680 | Implemented |
CO0343 # 05 Y:1995 | 05 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $980 | $900 | Implemented |
CO0343 # 06 Y:1995 | 06 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $930 | $1,250 | Implemented |
CO0343 # 07 Y:1995 | 07 | 1995 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $170 | $0 | Not Implemented |
CO0323 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $110,140 | $208,920 | Implemented |
CO0323 # 02 Y:1995 | 02 | 1995 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $18,310 | $55,500 | Implemented |
CO0323 # 03 Y:1995 | 03 | 1995 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $16,090 | $42,500 | Not Implemented |
CO0323 # 04 Y:1995 | 04 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $11,370 | $8,790 | Implemented |
CO0323 # 05 Y:1995 | 05 | 1995 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $9,950 | $34,080 | Not Implemented |
CO0323 # 06 Y:1995 | 06 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,520 | $4,210 | Implemented |
CO0323 # 07 Y:1995 | 07 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,000 | $7,800 | Not Implemented |
CO0320 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,920 | $57,500 | Not Implemented |