Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

214

matching recommendations
Reset
SIC 38 Instruments And Related Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0443 # 01 Y:1999 01 1999 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,232 $3,510 Not Implemented
MA0443 # 02 Y:1999 02 1999 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $656 $150 Implemented
MA0443 # 03 Y:1999 03 1999 INSTALL OCCUPANCY SENSORS $927 $325 Implemented
MA0443 # 04 Y:1999 04 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $287 $1,975 Implemented
MA0443 # 05 Y:1999 05 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $792 $60 Implemented
MA0443 # 06 Y:1999 06 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $169 $160 Not Implemented
MA0434 # 01 Y:1999 01 1999 OPTIMIZE PLANT POWER FACTOR $3,090 $8,125 Not Implemented
MA0434 # 02 Y:1999 02 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $652 $2,185 Not Implemented
MA0434 # 03 Y:1999 03 1999 INSTALL OCCUPANCY SENSORS $230 $130 Implemented
MA0434 # 04 Y:1999 04 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $71 $50 Implemented
MA0317 # 01 Y:1994 01 1994 OPTIMIZE PLANT POWER FACTOR $14,534 $20,294 Not Implemented
MA0317 # 02 Y:1994 02 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $10,949 $0 Implemented
MA0317 # 03 Y:1994 03 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,082 $2,792 Not Implemented
MA0317 # 04 Y:1994 04 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,897 $1,188 Implemented
MA0317 # 05 Y:1994 05 1994 INSTALL OCCUPANCY SENSORS $1,701 $1,440 Not Implemented
MA0317 # 06 Y:1994 06 1994 REUSE / RECYCLE/ SELL PAPER PRODUCTS $28,200 $700 Not Implemented
MA0317 # 07 Y:1994 07 1994 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $4,700 $0 Implemented
MA0300 # 01 Y:1994 01 1994 TURN OFF EQUIPMENT WHEN NOT IN USE $8,482 $0 Implemented
MA0300 # 02 Y:1994 02 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $686 $210 Implemented
MA0300 # 03 Y:1994 03 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,256 $16,853 Implemented
MA0300 # 04 Y:1994 04 1994 INSTALL OCCUPANCY SENSORS $4,090 $3,058 Implemented
MA0300 # 05 Y:1994 05 1994 DISCONNECT BALLASTS $1,042 $67 Implemented
MA0300 # 06 Y:1994 06 1994 REPAIR OR REPLACE STEAM TRAPS $5,397 $2,232 Implemented
MA0300 # 07 Y:1994 07 1994 TURN OFF EQUIPMENT WHEN NOT IN USE $1,658 $0 Not Implemented
MA0300 # 08 Y:1994 08 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $506 $0 Implemented