Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
82
matching recommendationsSIC | 38 | Instruments And Related Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0223 # 04 Y:2019 | 04 | 2019 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $550 | $0 | Implemented |
IC0223 # 03 Y:2019 | 03 | 2019 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $264 | $0 | Not Implemented |
IC0223 # 02 Y:2019 | 02 | 2019 | INSTALL SPECTRAL REFLECTORS / DELAMP | $267 | $2,000 | Not Implemented |
IC0223 # 01 Y:2019 | 01 | 2019 | INSTALL OCCUPANCY SENSORS | $210 | $24 | Not Implemented |
IC0222 # 03 Y:2019 | 03 | 2019 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $524 | $0 | Not Implemented |
IC0222 # 02 Y:2019 | 02 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $757 | $320 | Not Implemented |
IC0222 # 01 Y:2019 | 01 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,363 | $2,231 | Implemented |
BD0302 # 09 Y:2006 | 09 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $384 | $0 | Implemented |
BD0302 # 12 Y:2006 | 12 | 2006 | MINIMIZE WATER USAGE | $2,375 | $1,725 | Not Implemented |
BD0302 # 11 Y:2006 | 11 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $304 | $2,550 | Not Implemented |
BD0302 # 01 Y:2006 | 01 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,774 | $0 | Not Implemented |
BD0302 # 03 Y:2006 | 03 | 2006 | USE RADIANT HEATER FOR SPOT HEATING | $1,699 | $5,000 | Not Implemented |
BD0302 # 07 Y:2006 | 07 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1 | $0 | Not Implemented |
BD0302 # 05 Y:2006 | 05 | 2006 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $848 | $260 | Not Implemented |
BD0302 # 08 Y:2006 | 08 | 2006 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,195 | $1,550 | Not Implemented |
BD0302 # 10 Y:2006 | 10 | 2006 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $344 | $500 | Implemented |
BD0302 # 04 Y:2006 | 04 | 2006 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,130 | $0 | Implemented |
BD0302 # 06 Y:2006 | 06 | 2006 | INSTALL OCCUPANCY SENSORS | $835 | $1,050 | Not Implemented |
BD0302 # 02 Y:2006 | 02 | 2006 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $3,381 | $0 | Implemented |
BD0174 # 03 Y:2000 | 03 | 2000 | INSTALL OCCUPANCY SENSORS | $2,138 | $1,800 | Implemented |
BD0174 # 07 Y:2000 | 07 | 2000 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $526 | $500 | Implemented |
BD0174 # 02 Y:2000 | 02 | 2000 | $2,542 | $2,000 | Implemented | |
BD0174 # 06 Y:2000 | 06 | 2000 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $854 | $250 | Implemented |
BD0174 # 04 Y:2000 | 04 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $487 | $385 | Implemented |
BD0174 # 08 Y:2000 | 08 | 2000 | $218,400 | $61,810 | Implemented |